CLASSIC-LINE
ECO-LINE
Installation Guide
19
Sections for fireplaces without self closing door (A/B2)
For type A fireplaces
(= open and closed door operation), the table below shows
the minimum requirement in terms of number of connections:
VL inlet
(external air)
KL inlet
(ambient air)
KL inlet
(external air)
KL outlet
Axinit Front S
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
Ellipse S/K
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
Ellipse V
1
1
1
2
175 cm
2
175 cm
2
175 cm
2
350 cm
2
Jade Front S/K
1
2
1
3
175 cm
2
350 cm
2
175 cm
2
525 cm
2
Jade Tunnel S/K
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
Larimar Front S
1
2
1
3
175 cm
2
350 cm
2
175 cm
2
525 cm
2
Lumo S/K
1
2
1
3
175 cm
2
350 cm
2
175 cm
2
525 cm
2
Pi Classic V/S
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
Pi Compact V/S
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
Pi-ccolo Classic V/S
1
1
1
2
* 123 cm
2
175 cm
2
175 cm
2
350 cm
2
Pi-ccolo Compact V/S
1
1
1
2
* 123 cm
2
175 cm
2
175 cm
2
350 cm
2
Prisma S/K
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
Prisma V
1
1
1
2
175 cm
2
175 cm
2
175 cm
2
350 cm
2
Prismalo 500 S/K
1
2
1
3
175 cm
2
350 cm
2
175 cm
2
525 cm
2
Prismalo 500 V
1
1
1
2
175 cm
2
175 cm
2
175 cm
2
350 cm
2
Saphir Front S/K
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
Saphir Tunnel S/K
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
Saphir Giant S/K
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
Saphir Giant 500 S/K
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
720 Compact K
1
0
0
0
175 cm
2
0 cm
2
0 cm
2
0 cm
2
720 S/K (ECO)
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
720 V
1
1
1
2
175 cm
2
175 cm
2
175 cm
2
350 cm
2
720 Giant S/K
1
2
2
4
175 cm
2
350 cm
2
350 cm
2
700 cm
2
720 Giant V
1
1
1
2
175cm
2
175 cm
2
175 cm
2
350 cm
2
* colar-ø 125 mm
WARNING
In V-appliances (with built in ventilator) the number of collars can be
reduced because of the forced higher air volume. The ambient air in-
takes must be mounted symmetrically on the fireplace to ensure the
air heats evenly ant that the installation will not overheat on one
side!