background image

 

22 

EMERGENCY STOP: 

АВАРИЙНАЯ ОСТАНОВКА: 

When the machine or car maintained has abnormal,  
push “emergency stop” button “SB0” and locking, cut 
off all the operation circuit, other operation can not be 
work. 

При возникновении аварийной ситуации с 
подъёмником или автомобилем, нажмите кнопку 
аварийной остановки “SB0” и остановите подъёмник, 
блокируя подачу всех видов питания. 

NOT IN-PHASE STOP MACHINE: 

ОСТАНОВКА ПРИ РАЗНОЙ ВЫСОТЕ ПЛАТФОРМ: 

When two platforms are not at the same height during 
lifting and lowering operations, photocell leveling 
equipment will stop working immediately. According to 
the following process to adjust the platform level, only 
after two platforms are at the same height can put them 
into use. 

Если при подъёме или опускании платформы 
оказываются на разной высоте (> 5см), срабатывают 
фотодатчики и подъёмник блокируется. В 
соответствии с нижеописанным процессом 
регулировки уровня платформ, только при 
одинаковой высоте их расположения возможна 
эксплуатация подъёмника. 

 

Oil make-up “adjust” operation (normal 
service period): 

Процедура удаления воздуха из гидравлического 
контура 

 

After completion of machine installation and 
adjustment in the application process, the right 
platform is lower than the left one because of  

air in the oil cylinder not being excluded completely 
normal looses or leakage of the hydraulic oil. 

После завершения установки подъёмника и 
выполнения регулировки, правая платформа 
располагается ниже левой т.к. из-за особенностей 
монтажа в гидроцилиндре остаётся воздух. 

When conducting oil make-up operation, the platforms 
must not be loaded. 

При выполнении процедуры удаления воздуха 
платформы должны быть в ненагруженном состоянии 

Adjustment process as approach ‘5’ and ‘6’ of ‘Oil make-
up adjustment’. 

Выполните процедуру удаления воздуха как это 
описано в главе '5'. 

EMERGENCY MANUAL OPERATION FOR LOWERING 
(POWER FAILURE): 

РУЧНОЙ РЕЖИМ ОПУСКАНИЯ ПЛАТФОРМ (В 
СЛУЧАЕ ВНЕЗАПНОГО ОТКЛЮЧЕНИЯ ПИТАНИЯ) 

 

When lowering through manual operation, 
should observe the condition of platform at 
any time because there are vehicles on the  

platform. If there is something abnormal, screw down 
oil loop valve immediately. 

В режиме ручного опускания платформ следует 
постоянно контролировать положение платформ, 
т.к. на подъёмнике находится автомобиль. При 
возникновении внештатной ситуации, перекройте 
клапан ручного спуска. 

The process of manual operation:  Процедура ручного опускания 

платформ: 

- Firstly lift two lock latches of 
platform and use thin iron bar to  
fill up it. 

- Приподнимите защёлки 
фиксаторов и заблокируйте 
механизм при помощи 
металлического стержня. 

- Switch off the power button  
(avoid abruptly incoming 
electricity). Open the back cover  
of control box to find the descent 
valve A for lowering. 

- Обесточьте главый выключатель 
(во избежание внезапной подачи 
электропитания). Откройте заднюю 
крышку стойки управления для 
доступа к клапану ручного спуска А 
(рис.25). 

 

Picture / Рисунок 25 

- Loosen manual oil loop stud at the end of lowering 
electromagnetic valve core, and then the platform  
begins lowering. 

- Ослабьте вручную винт запорного 
электромагнитного клапана и платформы начнут 
опускаться. 

- After the machine has been lowered, screw down 
manual oil loop stud timely, the process of manual 
lowering comes to the end. 

- После окончательного опускания платформ, вновь 
закрутите винт запорного клапана. Процедура 
ручного спуска платформ завершена. 

 
Chapter 7 MAINTENANCE AND CARE 

 
Chapter 7 ОБСЛУЖИВАНИЕ И УХОД 

 

Only skilled and having been trained 
personnel is allowed to perform the 
operations. Check proceedings as 
following. 

Только опытный и уполномоченный персонал 
допускается к выполнению обслуживания и 
ухода. Выполняйте уход и обслуживание в 
соответствие с нижеприведёнными 
требованиями. 

- All bearings and hinges on this machine must be 
lubricated once a week by using an oilier. 

- Все подшипники и втулки подъёмника должны 
смазываться еженедельно при помощи маслёнки. 

- The safety gear, the upper and lower sliding blocks   
and other movable parts must be lubricated once o 
month. 

- Зубья фиксатора, верхние и нижние направляющие 
а также другие подвижные узлы должны смазываться 
ежемесячно. 

22 

Summary of Contents for RLSS-301

Page 1: ...Small scissor lift RLSS 301 3 0T RLSS 301 3 0 USER S MANUAL Operating Manual Instructions Ref B3 GC 3 0SS user s manual 20090821 19 2012 Serial No Year of Manufacture...

Page 2: ...peaking users However if you have any questions remarks or notes caused by this manual please contact our specialists immediately RUDETRANSSERVICE Ltd Russia 173003 Velikiy Novgorod B Saint Petersburg...

Page 3: ...y 3 11 Chapter 4 Installation 4 15 Chapter 5 Adjustment 5 18 Chapter 6 Operation 6 21 Chapter 7 Maintenance and care 7 22 Chapter 7 Failure and resolutions 8 23 Chapter 9 Appendix 9 26 9 1 Hydraulic s...

Page 4: ...hat all items specified in the delivery notes are included In case of missing parts possible defects or damage due to transport the person in charge or the carrier must be immediately informed Further...

Page 5: ...ized personnel from the licensed dealer or an service center authorized by the manufacturer The manufacturer declines all responsibility for injury to persons or damage to vehicles or objects when any...

Page 6: ...t for hydraulic failure and over loading So when the oil pipe bursts the machine will not fall quickly Use high quality hydraulic or electric element parts made in Italy Germany Japan and so on Own ma...

Page 7: ...lift weight kg 3000 3 Main machine Lift height mm 960 4 Platform initial height mm 105 5 Platform length mm 1450 6 Platform width mm 530 7 Lifting time s 50 8 Descent time s 60 9 Overall length mm 204...

Page 8: ...0 5A 220 10A Max Frequency Hz 50 Poles 4 Speed 1450 Building shape B14 Insulation class F When connecting the motor refer to the enclosed diagrams and the motor direction is clockwise PUMP Type P4 3 M...

Page 9: ...Clean the basic layer thickness of concrete 150mm the leveling of whole length 10mm 150 10 Remarks 1 Fix ground bolts before loading 1 2 The control box can be placed on the left or right side 2 Pict...

Page 10: ...ifting weight is 3000Kg 3000 THE MAX DIMENSION OF VEHICLE The following diagrams illustrate criteria used to define the operating limits of the lift The lower parts of the vehicle underbody could inte...

Page 11: ...s for personnel or lifting personnel Use as a press for crushing purposes Use as elevator Use as a lift jack for lifting vehicle bodies or changing wheels The manufacturer is not liable for any injury...

Page 12: ...to persons and or damage the lift the vehicle or other property RISK OF ELECTRIC SHOCK a specific safety notice placed on the lift in areas where the risk of electric shock is particularly high Risk...

Page 13: ...0 Picture 9 Picture 10 There is nothing abnormal should be left on the safety modules to prevent safety gear from occlude normally RISKS FOR PERSONNEL This heading illustrates potential risks for the...

Page 14: ...t and also the platforms must be kept clean Remove any oil spills immediately 12 Picture 11 Risk of impact Picture 12 Risk of slippine RISK OF ELECTRIC SHOCK Risk of electric shock that in area of the...

Page 15: ...st be 1000 mm at least taking into consideration the necessary space to work easily Because space for the control site and for possible runways in case of emergency is also necessary The 1000 The room...

Page 16: ...TION Connect the electrical and oil line according to the electric wiring diagram and oil line connection Only after connecting the hydraulic system can connect the air loop can not damage oil pipe wi...

Page 17: ...ipe COMPRESSED AIR PIPE CONNECTION Follow air loop diagram to connect air loop Only skilled and authorized person is allowed to perform the operations Connect 8 6 compressed air supply pipe to the air...

Page 18: ...kwise looking downward if not turn off the power then change the phase of the motor UP When turn on power there is high voltage in the control box only authorized person can operate it Turn on the air...

Page 19: ...ill affect the quality of solidity Adjust the parallel of the platform and the distance of two platforms as Picture 4 requires 4 Fix the anchor bolts with a percussion electric drill percussion drill...

Page 20: ...acles do the test again SB0 Load of machine test Drive the vehicle whose weight doesn t exceed maximum lifting weight to the platforms and then the driver leaves it Put the lift rubber cushion on the...

Page 21: ...machine should be lowered to the lowest position on ground and remove vehicle and cut off power supply Instructions on electric operation see the operation panel Picture 24 LIFTING Press UP button the...

Page 22: ...MERGENCY MANUAL OPERATION FOR LOWERING POWER FAILURE When lowering through manual operation should observe the condition of platform at any time because there are vehicles on the platform If there is...

Page 23: ...ates when forcing the contactor down with an isolation rod check the control circuit If the voltage at two ends of the contactor coil is normal replace the contactor 2 The motor does not run in liftin...

Page 24: ...coil of the lowering solenoid valve and check the right turn tightness of its end copper nut and so on 4 When press Lower button the machine is not lowered 5 The antiknock valve is blocked Remove the...

Page 25: ...e right and left platforms are not synchrono us and not in the same height 3 The oil make up stop valve can not be closed tightly and almost make up oil and adjust every day Replace oil make up stop v...

Page 26: ...raulic schematic drawing 9 1 1 3 sub cylinder 1 3 9 gear pump 9 2 4 main cylinder 2 4 10 flow control valve 10 5 stop valve 5 11 pump motor 11 6 check valve 6 12 filter 12 7 overflow valve 7 13 oil ta...

Page 27: ...27 9 APPENDIX 9 9 2 Oil pipe connection diagram 9 2...

Page 28: ...28 28 9 APPENDIX 9 9 3 Circuit diagram 220V 9 3 220...

Page 29: ...29 9 APPENDIX 9 9 4 Wiring diagram 220V 9 4 220...

Page 30: ...30 9 APPENDIX 9 9 5 Circuit diagram 380V 9 5 380...

Page 31: ...31 9 APPENDIX 9 9 6 Wiring diagram 380V 9 6 380...