VS-2400S 24 Ports VDSL2 Managed IP DSLAM with POTS splitter USER
’S MANUAL Ver.A3
32
Chapter 3.
Installation
3.1 Hardware Installation
This chapter describes how to install the IP DSLAM and establish network connections. You may install this IP DSLAM on any
level surface (table, shelf, 19 inch rack or wall mounting). However, please take note of the following minimum site requirements
before you begin.
3.2 Pre-Installation Requirements
Before you start actual hardware installation, make sure you can provide the right operating environment, including power
requirements, sufficient physical space, and proximity to other network devices that are to be connected. Verify the following
installation requirements:
Power requirements: AC 100V to 240 V at 50 to 60 Hz.
The IP DSLAM power supply automatically adjusts to the input voltage level.
The IP DSLAM should be located in a cool dry place, with at least 10cm/4in of space at the front and back for well
ventilation.
Place the IP DSLAM out of direct sunlight, and away from heat sources or areas with a high amount of electromagnetic
interference.
Check if network cables and connectors needed for installation are available.
Please note that the VS-2400S internal splitter, can pass through voice spectrum is 0 ~ 4KHz(POTS only).
Please note that the cutoff frequency of the splitter is 25kHz.