![RTscan RT206 User Manual Download Page 33](http://html1.mh-extra.com/html/rtscan/rt206/rt206_user-manual_1498167033.webp)
Enter Setup
23 *
* Exit Setup
RT20
6
User
G
u
ide
Level Trigger/Pulse Trigger
Level Trigger:
Decode session is activated and continued by constant active trigger signal. The decode
session ends once the barcode is decoded or decode session timeout expires.
Pulse Trigger:
Decode session is activated by electric pulse of trigger signal. The decode session
continues until the barcode is decoded or decode session timeout expires.
Auto Sleep
Auto Sleep allows the engine in the Trigger Mode to automatically enter the sleep or low power mode if
no operation or communication is performed for a time period (user programmable). When the engine is
in the sleep mode, receiving trigger signal or communication from the Host can awake the engine. The
engine returns to full operation within 100ms.
The parameter below specifies how long the engine remains idle (no operation or communication occurs)
before it is put into sleep mode. It is programmable in 1ms increments from 0ms to 65,535ms. The default
setting is 500ms. To learn how to program this parameter, see
Appendix 5
.
** Level Trigger
Pulse Trigger
** Enable Auto Sleep
Disable Auto Sleep
Time Period from Idle to Sleep