g. Program the Decoding Area
Example: Set the decoding area to 20% top, 80% bottom, 20% left and 80% right.
1. Scan the
Enter Setup
barcode.
2. Scan the
Specific Area Decoding
barcode. (See the
“
Specific Area Decoding
”
section in Chapter 4)
3. Scan the
Top of Decoding Area
barcode. (See the
“
Specify Decoding Area
”
section in Chapter 4)
4. Scan the numeric barcodes
“2”
and
“0”
.
5. Scan the
Save
barcode.
6. Scan the
Bottom of Decoding Area
barcode.
7. Scan the numeric barcodes
“
8
”
and
“0”
.
8. Scan the
Save
barcode.
9. Scan the
Left of Decoding Area
barcode.
10. Scan the numeric barcodes
“
2
”
and
“0”
.
11. Scan the
Save
barcode.
12. Scan the
Right of Decoding Area
barcode.
13. Scan the numeric barcodes
“
8
”
and
“0”
.
14. Scan the
Save
barcode.
15. Scan the
Exit Setup
barcode. (If you still need to program other parameter/feature, skip this step.)
h. Program the Custom Prefix/Suffix
Example: Set the custom prefix to
“CODE”
1. Check the hex values of
“CODE”
in the ASCII Table. (
“
CODE
”
: 43, 4F, 44, 45)
2. Scan the
Enter Setup
barcode.
3. Scan the
Set Custom Prefix
barcode. (See the
“
Set Custom Prefix
”
section in Chapter 6)
4. Scan the numeric barcodes
“4”
,
“3”
,
“4”
,
“F”
,
“4”
,
“4”
,
“4”
and
“5”
.
5. Scan the
Save
barcode.
6. Scan the
Exit Setup
barcode. (If you still need to program other parameter/feature, skip this step.)