![RTscan RT206 User Manual Download Page 127](http://html1.mh-extra.com/html/rtscan/rt206/rt206_user-manual_1498167127.webp)
117
RT20
6
User
G
u
ide
Parameter
Factory Default
Remark
Sense Mode
Decode Session Timeout
3,000ms
Applicable to Trigger mode, Sense
mode, Continuous mode.
100~3,600,000ms; 0: Infinite.
Image Stabilization Timeout
500ms
0~1,600ms
Timeout between Decodes
1000ms
Applicable to Sense mode,
Continuous mode.
0~65,535ms
Timeout between Decodes
(Same Barcode)
Disabled
1,500ms
0~65,535ms
Threshold Value of Illumination Change
2
1~20
Continuous Mode
Decode Session Timeout
3,000ms
Applicable to Trigger mode, Sense
mode, Continuous mode.
100~3,600,000ms; 0: Infinite.
Timeout between Decodes
1000ms
Applicable to Sense mode,
Continuous mode.
0~65,535ms
Timeout between Decodes
(Same Barcode)
Disabled
1,500ms
0~65,535ms
Scanning Preferences
Decode Area
Whole Area Decoding
Specify Decoding Area
40% top, 60% bottom,
40% left, 60% right
Illumination & Aiming
Illumination
Normal
Aiming
Normal
Beep & LED Notifications
Startup Beep
Enabled
Good Read Beep for
Non-Programming
Barcode
Notification
Enabled
Beep Type
Type 3
Beep Volume
Loud
Good Read Beep for Programming Barcode
Enabled
Good Read LED
Enabled
NGR (Not Good Read) Message
Do not transmit
None
Parameter
Factory Default
Remark