![RTscan RT206 User Manual Download Page 32](http://html1.mh-extra.com/html/rtscan/rt206/rt206_user-manual_1498167032.webp)
Enter Setup
** Exit Setup
22
RT20
6
User
G
u
ide
Trigger Mode
If the Trigger Mode is enabled, driving the TRIG pin on the host interface connector low activates a
decode session. The session continues until the barcode is decoded or decode session timeout expires
or the active trigger signal is no longer present. For good read, the engine transmits decoded data via
communication port. To activate another session, the Host
needs to first negate the trigger, waits 20ms or
longer and then drive the TRIG pin low.
** Trigger Mode
Decode Session Timeout
This parameter sets the maximum time decode session continues during a scan attempt. It is
programmable in 1ms increments from 100ms to 3,600,000ms. When it is set to 0, the timeout is infinite.
The default setting is 3,000ms. To learn how to program this parameter, see
Appendix 5
.
Decode Session Timeout