![Roxell Optimax Use And Assembly Manual Download Page 83](http://html.mh-extra.com/html/roxell/optimax/optimax_use-and-assembly-manual_1493852083.webp)
R
O
XEL
L
-
004
-
0
516
OPTI
MAX
-
IN
ST
ALL
A
T
ION
IN
STRU
CTI
O
NS
III
-
2
9
SAFETY SWITCH
1L1
3 L2
5 L3
T3
6
T2
4
2T1
21NC
NO
13
A1
14NO 22NC
A2
LC1D12
1/L1
3/L2
5/L3
2/T1
4/T2
6/T3
N
N
L1
L2
L3
N
STOP START
OFF
1L1
3L2
5L3
2T1
4T2
6T3
2T1 4T2 6T3 14NO A2
1L1 3L2 5L3 13NO A1
STOP START
OFF
1L1
3L2
5L3
2T1
4T2
6T3
2T1 4T2 6T3 14NO A2
1L1 3L2 5L3 13NO A1
L1 L2
PE
L1
PE
L1
PE
L2
L2
L1
PE
L3
L3
L3
L2
L1
PE
L3
L1
PE
L2 L3
L2
L3
1
2
2 1
1
2
2 1
W2
U2
V2
U1
V1
W1
6
3
12
1
2
1
2
2
1
Sw1
Sw2
Sw1
Sw2
MAXIMUM CABLE LENGTHS TO THE MOTORS: SEE PAGE III-35
Connection of start/stop conditions
Start/stop
condition
Level
swi
tch
Level switch
Junction box
Junction box
Control unit
Control unit
From motor starter
FEEDER PAN
100kg hopper
3x230V AC (IEC38)
Sense of rotation of the auger : see arrow on power unit. Attention : Compare setting of motor protection with data on motor name plate.
S
a
fe
ty
sw
itc
h
Max. total power
3hp (UL) or 3 kW
CONNECT EXTRA
START/STOP
CONDITIONS IN SERIES
First start/stop
condition
Last start/stop
condition
WI
RING
DIAGRAM
FOR
3
X230V
Connection of
5-wire sensor :
L2
L1
L3 PE
L2
PE
L1
L3
3 2 1
BU BN WH YE BK
3
1
2
5-wire
2-wire
Summary of Contents for Optimax
Page 8: ......
Page 9: ...I 1 PART I INSTRUCTIONS FOR THE USER ...
Page 10: ...OPTIMAX INSTRUCTIONS FOR THE USER ROXELL 004 2111 I 2 ...
Page 24: ...ROXELL 004 2414 OPTIMAX COMPONENTS II 2 GENERAL LAY OUT ...
Page 53: ...III 1 PART III INSTALLATION INSTRUCTIONS ...
Page 54: ...OPTIMAX INSTALLATION INSTRUCTIONS ROXELL 004 3503 III 2 NOTES ...
Page 56: ...OPTIMAX INSTALLATION INSTRUCTIONS ROXELL 004 2414 III 2 GENERAL LAY OUT ...
Page 91: ......