Tips and tricks
Programming the next day(s)
After confirming the programmed actions of a specific day (i.e. after
pressing the
<
button for 5 seconds), press the
pr
button once. You
can now select another day by using the
pi
and
pj
buttons
and restart consulting and programming.
Copying programmed actions to next day
In heating/cooling program it is possible to copy all programmed
actions of a specific day to the next day (e.g. copy all programmed
actions from "
1
" to "
2
").
To copy programmed actions to the next day, proceed as follows:
1
Press the
<
button.
The actual mode is blinking.
2
Use the
pi
and
pj
buttons to select the mode you want
to program.
The selected mode is blinking.
You can leave programming by pressing the
pr
button.
3
Press the
<
button to confirm the selected mode.
The actual day is blinking.
4
Select the day you would like to copy to the next day by means
of the
pi
and
pj
buttons.
The selected day is blinking.
You can return to step 2 by pressing the
pr
button.
5
Press the
<
and
pr
buttons simultaneously for 5 seconds.
After 5 seconds the display will show the next day (e.g. "
2
" if
"
1
" was selected first). This indicates that the day has been
copied.
You can return to step 2 by pressing the
pr
button.
Deleting one or more programmed actions
Deleting one or more programmed actions is done at the same time
as storing the programmed actions.
When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the
<
button for 5 seconds, you store all actions except
those with a higher action number than the one that is displayed.
E.g. when the
<
button is pressed when action number 3 is
displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.
Deleting a mode
1
Press the
<
button.
The actual mode is blinking.
2
Use the
pi
and
pj
buttons to select the mode you want
to delete (quiet mode
s
, booster heating
m
or domestic water
heating
w
).
The selected mode is blinking.
3
Press the
<
and
ba
button simultaneously for 5 seconds to
delete the selected mode.
Deleting a day of the week (cooling or heating mode)
1
Use the
=
button to select the operation mode (cooling or
heating) you want to delete.
2
Press the
<
button.
The actual mode is blinking.
3
Press the
<
button to confirm the selected mode.
The actual day is blinking.
4
Select the day you would like to delete by means of the
pi
and
pj
buttons.
The selected day is blinking.
5
Press the
<
and
ba
button simultaneously for 5 seconds to
delete the selected day.
O
PERATING
THE
REMOTE
ALARM
OPTION
The optional EKRP1HB remote alarm address card can be used to
remotely monitor your system. This address card offers 2 voltage free
outputs.
■
Output 1 = alarm output: this output will be enabled when your
unit is in error condition.
■
Output 2 = ON/OFF output: this output will be enabled when
your unit is in ON condition.
For more details about the wiring connections of this option, refer to
the wiring diagram of the unit.
F
IELD
SETTINGS
The unit should be configured by the installer to match the installation
environment (outdoor climate, installed options, etc.) and user
demand. Thereto, a number of so called field settings are available.
These field settings are accessible and programmable through the
user interface.
Each field setting is assigned a 3-digit number or code, for example
[5-03], which is indicated on the user interface display. The first digit
[5] indicates the 'first code' or field setting group. The second and
third digit [03] together indicate the 'second code'.
A list of all field settings and default values is given under "Field
settings table" on page 16. In this same list, we provided for 2
columns to register the date and value of altered field settings at
variance with the default value.
A detailed description of each field setting is given under "Detailed
description" on page 11.
Procedure
To change one or more field settings, proceed as follows.
1
Press the
z
button for a minimum of 5 seconds to enter FIELD
SET MODE.
The
$
icon (3) will be displayed. The current selected field
setting code is indicated
;
(2), with the set value displayed to
the right
-
(1).
2
Press the
bgi
button to select the appropriate field
setting first code.
3
Press the
bgj
button to select the appropriate field
setting second code.
4
Press the
pfi
button and
pfj
button to change
the set value of the select field setting.
5
Save the new value by pressing the
pr
button.