LCAC R32 Series
124
Service manual
2.5 Capacity tables for 55K
a) Cooling
TC:
Total Capacity;
SHC:
Sensible Heat Capacity;
PI:
Power Input
Indoor
Outdoor temperature (DB, °C)
20
25
30
35
40
DB
WB
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
°C
°C
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
20
14
15,80
12,32
4,12
15,12
12,10
4,49
14,44
11,84
4,86
13,62
11,44
5,28
13,21
11,36
5,65
22
16
16,63
12,72
4,16
15,91
12,49
4,54
15,20
12,23
4,91
14,34
11,83
5,34
13,91
11,75
5,71
25
18
17,51
13,13
4,21
16,75
12,90
4,58
16,00
12,64
4,96
15,09
12,22
5,39
14,64
12,15
5,77
27
19
17,86
13,22
4,23
17,09
12,99
4,61
16,32
12,73
4,99
15,40
12,32
5,42
14,94
12,25
5,80
30
22
19,11
13,86
4,27
18,29
13,63
4,65
17,47
13,36
5,04
16,48
12,95
5,47
15,98
12,87
5,86
32
24
19,83
14,18
4,29
18,97
13,95
4,68
18,12
13,68
5,06
17,09
13,25
5,50
16,58
13,18
5,89
b) Heating
TC:
Total Capacity;
PI:
Power Input
Indoor
Outdoor temperature (DB, °C)
-20
-15
-10
-7
-2
2
7
12
17
DB
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
°C
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
15
9,37
4,86
11,25
5,12
13,68
5,64
14,06
5,38
15,15
5,61
16,03
5,79
18,75
5,17
18,18
4,81
17,43
4,65
18
9,24
4,94
11,08
5,20
13,49
5,72
13,85
5,46
14,93
5,69
15,79
5,88
18,47
5,25
17,92
4,88
17,18
4,73
20
9,10
5,01
10,92
5,28
13,29
5,81
13,65
5,54
14,71
5,78
15,56
5,97
18,20
5,33
17,65
4,96
16,93
4,80
22
8,92
5,06
10,70
5,33
13,02
5,87
13,38
5,60
14,42
5,84
15,25
6,03
17,84
5,38
17,30
5,01
16,59
4,84
24
8,83
5,11
10,59
5,38
12,89
5,93
13,24
5,65
14,27
5,90
15,09
6,09
17,65
5,44
17,12
5,06
16,42
4,89
25
8,74
5,14
10,48
5,41
12,75
5,95
13,10
5,68
14,12
5,92
14,94
6,12
17,47
5,46
16,95
5,08
16,25
4,92
27
8,65
5,19
10,37
5,46
12,62
6,01
12,97
5,74
13,98
5,98
14,78
6,18
17,29
5,52
16,77
5,13
16,08
4,96
PART 7. CAPACITY TABLES
3. JATO - CEILING-FLOOR
3.1 Capacity tables for 18K
a) Cooling
TC:
Total Capacity;
SHC:
Sensible Heat Capacity;
PI:
Power Input
Indoor
Outdoor temperature (DB, °C)
20
25
30
35
40
DB
WB
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
TC
SHC
PI
°C
°C
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
kW
20
14
5,44
4,24
1,25
5,20
4,16
1,36
4,97
4,07
1,47
4,69
3,94
1,60
4,55
3,91
1,71
22
16
5,72
4,38
1,26
5,48
4,30
1,37
5,23
4,21
1,49
4,93
4,07
1,62
4,79
4,04
1,73
25
18
6,03
4,52
1,27
5,77
4,44
1,39
5,51
4,35
1,50
5,19
4,21
1,63
5,04
4,18
1,75
27
19
6,15
4,55
1,28
5,88
4,47
1,39
5,62
4,38
1,51
5,30
4,24
1,64
5,14
4,22
1,75
30
22
6,58
4,77
1,29
6,29
4,69
1,41
6,01
4,60
1,52
5,67
4,46
1,66
5,50
4,43
1,77
32
24
6,82
4,88
1,30
6,53
4,80
1,41
6,24
4,71
1,53
5,88
4,56
1,66
5,71
4,54
1,78
Summary of Contents for J100Wi
Page 1: ...LCAC R32 SERIES Tenji W Jato W Nevo W ENG Service manual ...
Page 13: ...LCAC R32 Series 13 Service manual PART 2 INDOOR UNITS 1 5 2 Units 30 42K a Cooling b Heating ...
Page 14: ...LCAC R32 Series 14 Service manual PART 2 INDOOR UNITS 1 5 3 Units 48 55K a Cooling b Heating ...
Page 18: ...LCAC R32 Series 18 Service manual PART 2 INDOOR UNITS 1 10 1 Wiring diagram for T140Wi T160Wi ...
Page 44: ...LCAC R32 Series 44 Service manual PART 2 INDOOR UNITS 3 10 FIELD WIRING ...
Page 131: ...LCAC R32 Series 131 Service manual NOTES ...
Page 132: ...www rotenso pl email info rotenso pl Installer stamp ...