77
User manual
Hydrobox module AQMS80X1i
EN
PART 2. INSTALLATION MANUAL
DO NOT install unit in the following locations:
[
Near an obstacle that will block air inlets and outlets
[
Near a public street, crowded areas, or where noise from the unit will disturb others
[
Near animals or plants that will be harmed by hot air discharge
[
Near any source of combustible gas
[
In a location that is exposed to large amounts of dust
[
In a location exposed to a excessive amounts of salty air
Special considerations for extreme weather
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90° angle to the
direction of the wind. If needed, build a barrier in front
of the unit to protect it from extremely heavy winds.
See Figures below.
If the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or snow. Be careful not to obstruct air flow around
the unit.
If the unit is frequently exposed to salty air (seaside):
Use outdoor unit that is specially designed to resist corrosion.
Strong wind
Strong wind
Wind Bafe
Strong wind
Seal
Step 2: Install drain joint (Heat pump unit only)
Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit. Note that
there are two different types of drain joints depending on the type of outdoor unit.
If the drain joint comes with a rubber seal (see Fig. A ), do the following:
1. Fit the rubber seal on the end of the drain joint that will connect to the outdoor unit.
2. Insert the drain joint into the hole in the base pan of the unit.
3. Rotate the drain joint 90° until it clicks in place facing the front of the unit.
4. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during
heating mode.
If the drain joint doesn’t come with a rubber seal (see Fig. B ), do the following:
1. Insert the drain joint into the hole in the base pan of the unit. The drain joint will click in place.
2. Connect a drain hose extension (not included) to the drain joint to redirect water from the unit during
heating mode.
Base pan hole of
outdoor unit
Seal
Drain joint
(A)
(B)