58
User manual
Hydrobox module AQMS80X1i
EN
PART 1. OWNER’S MANUAL
NOTE:
The functions “HEAT” and “DHW” can only be selected when the corresponding equipment is installed.
2.5. Temperature setting
Press
key to enter the hot water setting temperature adjustment, press “ ” or “ ” to select the temperature.
Setting Temperature Range : 35~55°C(95~131°F).
3.5.1.°C & °F scale selection
Press the buttons “ ” or “ ” for 3 seconds will alternate the temperature display between the °C & °F scale.
2.6. Child lock function
Press the buttons
and
for 3 seconds to activate the child lock function
and lock all buttons on the wire controller
(Pic. 3.6.1).
Press the buttons again for 3 seconds to deactivate the child lock function.
When the child lock function is activated,the mark appears.
2.7. Energy saving button (ECO)
(Effective in heating mode):
Press button
, the indoor unit operates in economy mode,press again, exit this mode (it may be ineffective
for some models)
2.8. AUXILIARY ELECTRICAL HEATER function
Press this button to turn on or off the auxiliary electric heat function.
(Pic. 3.8.1)
• Press this button, it is forced to turn on the electric auxiliary heating (the
user has a turbo heating demand).
• Electric auxiliary heat is turned on when it meets the mandatory opening
condition.
• Press Again, it is the electric auxiliary heat automatic control. Electric
auxiliary heat is turned on at the most suitable time according to the control
scheme, considering energy saving and comfort.
2.9. Set button:
Press
button for 2 seconds to enter the query mode.
1. After entering the query mode, the time area at the lower right corner displays CL, indicating the cleaning
function.
2. Press
button to enter the setting interface, press “ ” and “ ” to select
on or off, then press Confirm button to confirm, select on to indicate the
cleaning function is turned on, at the same time, the interface will display CL.
(Pic. 3.9.1)
3. Press Power button or Back button to exit, or the internal machine
finishes the cleaning function to exit.
(Pic. 3.9.2)
4. Press the buttons “ ” and “ ” can choose other parameter query.
• When FB is selected, it means the forced return function. Press set to
enter the setting interface, and select whether to enable forced return.
When on is selected, it means enabled.
• When CB is selected, it means the disinfection function. Press set to enter
the setting interface, select whether to enable disinfection function.
(Pic. 3.6.1
)
(Pic. 3.8.1
)
(Pic. 3.9.1
)
(Pic. 3.9.2
)