SAFETY PRECAUTIONS
TAKE NOTE OF FUSE SPECIFICATIONS
The air conditioner’s circuit board (PCB) is designed with a fuse to provide overcurrent protection.
The specifications of the fuse are printed on the circuit board ,examples of such are T5A/250VAC and
T16A/250VAC.
WARNINGS FOR PRODUCT INSTALLATION
• Installation must be performed by an authorized dealer or specialist. Defective installation can cause
water leakage, electrical shock, or fire.
• Installation must be performed according to the installation instructions. Improper installation can
cause water leakage, electrical shock, or fire.
• Contact an authorized service technician for repair or maintenance of this unit. This appliance shall be
installed in accordance with national wiring regulations.
• Only use the included accessories, parts, and specified parts for installation. Using non-standard parts
can cause water leakage, electrical shock, fire, and can cause the unit to fail.
• Install the unit in a firm location that can support the unit’s weight. If the chosen location cannot
support the unit’s weight, or the installation is not done properly, the unit may drop and cause serious
injury and damage.
• Install drainage piping according to the instructions in this manual. Improper drainage may cause
water damage to your home and property.
• For units that have an auxiliary electric heater, do not install the unit within 1 meter (3 feet) of any
combustible materials.
Do not
install the unit in a location that may be exposed to combustible gas leaks. If combustible gas
accumulates around the unit, it may cause fire.
• Do not turn on the power until all work has been completed.
• When moving or relocating the air conditioner, consult experienced service technicians for
disconnection and reinstallation of the unit.
• How to install the appliance to its support, please read the information for details in “indoor
unitinstallation” and “outdoor unit installation” sections .
NOTE ABOUT FLUORINATED GASSES (R32)
• This air-conditioning unit contains fluorinated greenhouse gasses. For specific information on the type
of gas and the amount, please refer to the relevant label on the unit itself or the “Owner’s Manual -
Product Fiche ” in the packaging of the outdoor unit. (European Union products only).
• Installation, service, maintenance and repair of this unit must be performed by a certifiedtechnician.
• Product uninstallation and recycling must be performed by a certified technician.
• For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO2 equivalent
or more, but of less than 50 tonnes of CO2 equivalent, If the system has a leak- detection system
installed, it must be checked for leaks at least every 24 months.
• When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.