2.13.1. WLAN
When the WLAN icon flashes, press the Confirm “ “ button to enter the AP distribution mode. If the AP
mode is successfully entered, the LCD flashes the AP character. If the distribution network is not successful,
the AP mode will exit automatically after 8 minutes. After the successful distribution network, if the network is
connected, the WLAN icon will be on; if the network is disconnected for 15 minutes, the WLAN icon will be off.
2.13.2. Turbo Heating
In the HEAT mode or HEAT and DHW mode, press the FUNC. button to select the TurboHeating icon and
press the Confirm button “ “to turn on or off the Turbo Heating function. After the turbo heating function
is turned on, the energy saving function is cancelled.
2.13.3. Turbo domestic hot water
In the DHW mode or HEAT and DHW mode, press the FUNC. button to select the Turbo domestic hot water
icon and press the Confirm button “ “ to turn on or off the function.
2.13.4. Outgoing function
Press the FUNC. button to select the Outgoing function icon, and press the Confirm button “ “ to turn on
or off the function.
After opening the out function, the set temperature of heating mode is 25°C, and the set temperature of
hot water mode is 35°C.
After canceling the out of office function, the set temperature will return to the original set temperature.
2.13.5. Energy saving
In the HEAT mode or HEAT and DHW mode, press the ECO button to select the Energy saving icon and press
the Confirm “ “ button to turn on or off the function.
After the energy saving function is turned on, the turbo heating function is cancelled.
2.13.6. Disinfection
Under DHW mode or HEAT and DHW mode, press the FUNC. button to select the disinfection icon, press the
Confirm “ “ button to turn on or off the disinfection function.
The error displayed on the wire controller are different from those on the unit. If error code appears, please
check the “Owner’s And Installation Manual” and ”SERVICE Manual”.
2.14. Fault alarm handing
If the system does not properly operate except the above mentioned cases or the above mentioned
malfunctions is evident, investigate the system according to the following procedures.
No.
Malfunction & protection define
Display digital tube
1
Error of communication between wire controler and
indoor unit
The error displayed on the wire controller are dierent from those on the unit. If error code appears, please check
the “Owner’s And Installation Manual” and “SERVICE Manual”.
2.15.Technical indication and requirement
EMC and EMI comply with the CE certification requirements.
PART 1. OWNER’S MANUAL