Display Description
LED Display
Indicator Status
Description
When the power is on, the screen will first display "888"
and the default mode "OPA", then the raw water
solenoid valve starts and feeds water.
Startup Flush: the screen displays "020~000", and
the countdown is 20 seconds.
Start the pure water production, the number
displayed on the screen is the TDS value of the pure
water, and the indicator "PUMP" lights up.
Start the Timed Flush: The default setting is every 2
minutes flushing 10 seconds, and the screen
displays a countdown of "A10~A00".
When the water tank is full, start to Tank-Full flush
for 30 seconds, and the system will stand by.
When the water tank is low (below the set pressure),
the display shows "LO", the indicator LOW/INLET
lights up, and the system will continue to feed water.
The wastewater end will continue to drain until the
inlet water pressure reaches the set value. When the
indicator "LO" lights off, the system will flush for 10
seconds and resumes water production.
Start the Manual Flush: Press the SET/FLUSH
button once, and the system will start a 10-second
flush. Then the RO high-pressure pump resumes
operation and starts to produce water.
The default TDS range is 0 to 999 ppm, and the
display flashes beyond the range of 999. (OPA
mode is suitable for raw water TDS <1,000ppm)
NOTE
If the pressure cannot reach the default value, please turn off the power and check your inlet water
pressure. It is recommended to double confirm with the factory your raw water inlet pressure before installation.