background image

12 

 

Display Description 

 

 

  

LED Display   

 

Indicator Status

 

                            Description 

 

When the power is on, the screen will first display "888
and the default mode "OPA", then the raw water 
solenoid valve starts and feeds water. 

 

Startup Flush: the screen displays "020~000", and 
the countdown is 20 seconds. 

 

Start the pure water production, the number 
displayed on the screen is the TDS value of the pure 
water, and the indicator "PUMP" lights up. 

 

Start the Timed Flush: The default setting is every 2 
minutes flushing 10 seconds, and the screen 
displays a countdown of "A10~A00".  

 

When the water tank is full, start to Tank-Full flush 
for 30 seconds, and the system will stand by. 

 

When the water tank is low (below the set pressure), 
the display shows "LO", the indicator LOW/INLET 
lights up, and the system will continue to feed water. 
The wastewater end will continue to drain until the 
inlet water pressure reaches the set value. When the 
indicator "LO" lights off, the system will flush for 10 
seconds and resumes water production. 
 
 
 

 

 

Start the Manual Flush: Press the      SET/FLUSH 
button once, and the system will start a 10-second 
flush. Then the RO high-pressure pump resumes 
operation and starts to produce water. 

 

The default TDS range is 0 to 999 ppm, and the 
display flashes beyond the range of 999. (OPA 
mode is suitable for raw water TDS <1,000ppm) 

NOTE

 If the pressure cannot reach the default value, please turn off the power and check your inlet water 

pressure. It is recommended to double confirm with the factory your raw water inlet pressure before installation.

 

 

 

Summary of Contents for KSRO Series

Page 1: ...KSRO Series Reverse Osmosis System Installation Manual...

Page 2: ...esigned with a fixed recovery rate of 60 65 by using ROTEK extra large flow RO membranes that can produce 4000 6000GPD 650 1000LPH of permeate water flow which means it can produce more pure water at...

Page 3: ...aw requires it or you prefer to we recommend using a professionally licensed installer or plumber who meets the requirements of this system All O Rings fittings filter canisters and Teflon tape wear o...

Page 4: ......

Page 5: ...Components List 5 System Overview 6 System Guide 7 Installation Procedure 8 System Startup Operation 10 C5TM RO Controller 11 Flow Meter and Pressure Gauges 13 Troubleshooting 13 System Maintenance 14...

Page 6: ......

Page 7: ...om for filter replacements System Specifications KSRO system recovery rate is calculated based on the volume of flush water discharged Recovery Rate Permeate Flow Permeate Flow Discharged Flush Flow P...

Page 8: ...olids 1000 ppm Organics 1 ppm Turbidity SDI 5 Temperature 5 to 40 C pH 3 11 Silica 1 0 ppm Iron 0 01 ppm Pressure 240 kPa These specifications should be met in order to have the reverse osmosis system...

Page 9: ...using ROTEK s existing standard pretreatment module of course it can also be customized according to your raw water conditions KSRO Pretreatment Unit Optional 1 20 filter housing x 1pcs 5 m GAC filte...

Page 10: ...Ensure that power lead is rated to carry the current draw of the system A minimum electrical wire diameter of 3 5mm is recommended 3 The external storage tank level contact switch should be connected...

Page 11: ...O Main Unit ROTEK XL 4040 RO Membrane Flexible PE Tubing 5 m Filter Housing Wrench Installation Manual Solenoid Valve Diaphragm KSRO4000 and KSRO6000 have the same standard installation and operation...

Page 12: ...e Gauge 7 Bar 6 RO Permeate Flow Meter 5GPM 10GPM 7 RO Membrane Inlet Pressure Gauge 35 Bar 8 Pump Contactor 9 3 4 Inlet Solenoid Valve 10 LF 20 Low Pressure Switch shut off pressure at 1 bar 11 LPE2...

Page 13: ...the impure water rejected by the Reverse Osmosis membrane is flushed out This manual uses KSRO4000 for demonstration The RO Permeate Flow Meter can be 5GPM 10GPM is subject to the model you purchased...

Page 14: ...on the label should head downward Place back the PP end cap of the membrane vessel and Make sure to lock the water outlet pipe and safety ring are secure NOTE Do not overtighten Step 2 Connect the pre...

Page 15: ...he sink pipe a floor drain or another design that discharges wastewater Step 5 Take the blue wire and connect this to the float level sensor in the permeate storage tank This allows the RO to turn on...

Page 16: ...alve on top of the Pre filter cap to release any air pressure that may have built up in the system until water springs from the breather valve This step usually only needs to be performed at the first...

Page 17: ...RO system will stop making water and stand by Flush Green The system is running an automatic flush cycle of the RO membrane Pump Green The RO high pressure pump is running and making water Low Red Th...

Page 18: ...nk is low below the set pressure the display shows LO the indicator LOW INLET lights up and the system will continue to feed water The wastewater end will continue to drain until the inlet water press...

Page 19: ...se use the water supply storage tank and booster pump to supply water to the RO system and prevent the system from circulating Why is the output of my RO pure water getting less 1 If the output of RO...

Page 20: ...e chapter Vacation Mode How to Change the Pre filter Housing Recommended about every 3 months depending on water use 1 You will need a clean cloth dish soap and 20 PP Cartridge 5um filter The system m...

Page 21: ...the new 4040 RO Membrane and insert the new RO Membrane in the Membrane Housing in the correct direction you noted earlier 4 Make sure to push the Membrane in firmly then close the vessel by tightenin...

Page 22: ...solved and well mixed before circulating the solutions through the membrane elements 2 It is recommended the membrane elements be flushed with good quality chlorine free water after cleaning Permeate...

Page 23: ...g If the elements are heavily fouled using a higher flow rate is possible up to the maximum pressure drop across the membrane permissible check with membrane manufacturer s data sheets With higher flo...

Page 24: ...tes excessive pressure drop may be a problem The maximum recommended pressure drops for most common membranes are 100kPa per element or 340 kPa per multi element vessel whichever value is more limitin...

Page 25: ...age and power supply What is the discharge rate The typical discharge rate range of KSRO is 1 2 gallon for every one gallon produced Your water pressure incoming water quality and water temperature wi...

Page 26: ...ertically on a clean surface until dry 3 Place each filter individually in a sealed air tight plastic wrap and place in the refrigerator for the duration if filter is reusable and less than 3 months o...

Page 27: ...ime Covered This warranty is effective for 1 full year from the date of the original purchase Not Covered This warranty does not cover labor for removal or installation accumulation of dirt or grime y...

Page 28: ...e operating hours Water inlet pressure kPa 140 650 kPa Membrane inlet pressure kPa 700 1400 Pure water flow rate lpm 3 5lpm Membrane Feed Water Conductivity or TDS Pure Water Conductivity or TDS Salt...

Reviews: