9
Step 3
Connect a sufficient length of 1/2" diameter hose to
the fitting marked "Pure Water" on the rear of the
panel.
Connect this hose to a pure water (permeated water)
storage tank, to your faucet, or to any other device
you need to provide pure RO water.
Step 4
Connect a sufficient length of 3/4" diameter water
tubing to the outlet of the membrane flush solenoid
valve and connect it directly to the drain or to fitting
on the sink pipe, a floor drain, or another design that
discharges wastewater.
Step 5
Take the blue wire and connect this to the float level
sensor in the permeate storage tank. This allows the
RO to turn on and off automatically according to the
treated water storage tank level.
Step 6
Connect the power cable to a suitable plug or to the
other control panel. Ensure that the available power
matches the power requirements of the system and
that the power cables are rated to carry the current
load of the system.
Pure Water
Outlet
Drain
Line
Blue Wire
to connect
the Float
Level
Sensor
Power
Requirements
220V
Float
Level
Sensor