background image

25

WARRANTY

ROTARY GATE SYSTEMS, INC. 5 YEAR LIMITED WARRANTY

Rotary  Gate  Systems,  Inc.  warrants  to  the  original  installing  dealer  of  the  SL -1000  R  gate  operator
that it will be free from defects in materials and workmanship for a period of five (5) years from the
date  of  original  purchase  from  Rotary  Gate  Systems.

This  warranty  applies  only  to  the  SL -1000  R

gate operator and not to the APeX controller.  A two (2) year warranty applies to the APeX controller,
power  transformer  and  power  box.    Rotary  Gate  Systems,  Inc.  warrants  to  the  original  installing
dealer of the unit that it will be free from defects in materials and workmanship for a period of two (2)
years from the date of original purchase from Rotary Gate System, Inc.

If  the  SL-1000  R  requires  service,  contact  the  dealer  who  originally  installed  it.  If  that dealer  is  not
available, call 1-877-331-4747 to be referred to a dealer in your area.

THIS  WARRANTY  APPLIES  ONLY  TO  THIS  PRODUCT  WHEN  INSTALLED  BY  A  QUALIFIED
DEALER  AND  NOT  TO  ANY  ACCESSORIES,  THE  GATE  PANEL  ITSELF,  OR  ANY  GATE
SUPPORT  HARDWARE.  THIS  WAR RANTY  ONLY  COVERS  THE  GATE  OPERATOR  AND
CONTROLLER.  THE  INSTALLING  DEALER  MAY  PROVIDE  DIFFERING WARRANTIES  FOR  HIS
SERVICES.

ALL WARRANTIES (IMPLIED OR UNIMPLIED) ARE LIMITED TO A PERIOD OF FIVE (5) YEARS.
SOME  STATES  DO  NOT  ALLOW  LIMITATIONS  ON  HOW  LONG AN  IMPLIED WARRANTY  MAY
LAST, SO THIS LIMITATION MAY NOT APPLY TO YOU.

ROTARY GATE SYSTEMS, INC. shall not be held liable for any consequential, incidental or special
damages  in  connection  with  the  installation,  use  or  inability  to  use  this  product.  The  l imitations  of
liability for ROTARY GATE SYSTEMS, INC. shall be limited to repair or replacement of this product.

Some states do not allow exclusion or limitation of consequential, incidental or special damages, so
the preceding exclusions may not apply to  you. This warranty gives you specific legal rights and you
may have other rights which may vary from state to state.

This warranty is not transferable.

Summary of Contents for SL-1000 R

Page 1: ...1 SL 1000 R RESIDENTIAL LIGHT COMMERCIAL SLIDE GATE OPERATOR MADE IN U S A ROTARY GATE SYSTEMS INC ALL RIGHTS RESERVED 2008 REV 1 1 1 877 331 4RGS 4747...

Page 2: ...t reversing Sensor Easy troubleshooting with easy to interpret LED display 200 cycles per day when used on properly installed gates Input for non contact secondary entrapment protection device In addi...

Page 3: ...t setup Stagger mode Stagger delay time Auxiliary relay mode Reverse delay time Low power mode Power failure mode Soft start stop duration Reset cycle count Maintenance alert trigger Mid travel stop p...

Page 4: ...ecurity personnel Approved Obstruction Detection Devices The following contact or non contact obstruction detection devices have been approved for use with this slide gate operator as part of a UL325...

Page 5: ...or installation A good earth ground is necessary to allow the controller s built in surge and lightning protection circuitry to work effectively All ROTARY GATE SYSTEMS gate operators are supplied wit...

Page 6: ...ety devices have been included in the layout of the system o A separate pedestrian gate has been included in the gate layout in a location safe from contact with the vehicular gate when it is in the f...

Page 7: ...7 Access Control Devices The SL 1000 R is compatible with any type of access control device which provides a dry contact relay for activation Installation Figure 2 Gate and Post Layout...

Page 8: ...8 Figure 3...

Page 9: ...st 7 Using a 5 16 drill drill a hole into the post through each of the four holes in the mounting plate Tap the holes using a 3 8 16 tap This step may be eliminated if welding the mounting plate to th...

Page 10: ...ontrol panel Secure the operator motor wire so as to ensure that it will stay c lear of the pinion gear rack gear and gate panel when in motion If necessary the motor wires from the operator can be ad...

Page 11: ...UT TERMINALS SINGLE INPUT TERMINALS PRIMARY SECONDARY COMM LINK TERMINALS FIRE DEPT INPUT TERMINALS ACCESSORY POWER TERMINALS DISPLAY PROGRAMMING BUTTONS INPUT POWER TERMINALS PLUG IN LOOP DETECTOR CO...

Page 12: ...OR CURRENT HAS EXCEEDED THE OPEN CURRENT SETTING WHILE OPENING SET MAXIMUM OPEN CURRENT OPEN OBSTR MGT 2 SET OPEN OBSTRUCTION TERMINAL CONNECTED TO COMMON BY BEAM OR SAFETY EDGE OR SIGNAL FROM MGT OBS...

Page 13: ...HEN STOP AGAIN AT THIS TIME THE AUTO CLOSE TIMER IS DISABLED AND A RENEWED INPUT WILL BE REQUIRED TO START THE GATE AGAIN SHOULD THE GATE BE RESTARTED AND THE OBSTACLE SIGNAL OCCUR AGAIN PRIOR TO REAC...

Page 14: ...CH PHOTOEYE FOR CLOSE OBSTRUCTION FIRE ACCESS SWITCH SOLENOID LOCK EXTERNAl POWER PHOTOEYE FOR OPEN OBSTRUCTION SINGLE CHANNEL RADIO RECEIVER MAGLOCK GATE EDGE SENSOR FOR REVERSE TWO CHANNEL RADIO REC...

Page 15: ...T 110 VAC 110 VAC WIRES ARE UNDER TRANSFORMER MOTOR Connect motor wires from SL 1000 R gate operator LIMIT SWITCHES Connect to the wires from the limit switches Black wires go to COMMON RED to OPEN or...

Page 16: ...f the gate For left hand installations program the controller for left hand operation WHEN CHANGING TO LEFT HAND OPERATION YOU MUST ALSO REVERSE THE MOTOR LEADS IN ADDITION Dual Gate Enable The factor...

Page 17: ...If the close current load exceeds the programmed maximum load number the operator will stop reverse a short distance then stop again If after restart the overload or a close obstacle happens again be...

Page 18: ...o ne operator for delayed opening and the other operator for delayed closing The Stagger Delay Time programming function see below sets the length of the delay NOTE This function will only be displaye...

Page 19: ...is set for Open Immediate alternately the controller can be set for Fail Secure Open Immediate or Close Immediate Fail Safe If the AC power fails and the battery voltage drops below 17 volts 5 second...

Page 20: ...med to open for 1 to 99 seconds the stop before reaching the open limit When a Mid travel stop position time has been programmed the gate will still fully open if the Fire Department input is triggere...

Page 21: ...s function will not erase radio transmitters Transmitters must be deleted with the two functions above DO NOT RESET CONTROLLER WITHOUT CONSULTING TECHNICAL SUPPORT AT 877 331 4747 FUNCTION CL ENTER WH...

Page 22: ...osing at any time Single Input Opens the gate if it s closed and closes th e gate if it s open open close programming option Activating the input while the gate is moving will reverse the gate Can be...

Page 23: ...run alarm will beep twice as fast and continue for five minutes after the gate stops The sounder will chirp every five seconds when the gate is idle Correct the trouble close case replace battery or...

Page 24: ...ndicated by EN 04 on the APeX display To clear this error press the RESET button on the out side of the control box and give the system an OPEN or CLOSE signal Model SL 1000 R Maintenance Battery Main...

Page 25: ...in your area THIS WARRANTY APPLIES ONLY TO THIS PRODUCT WHEN INSTALLED BY A QUALIFIED DEALER AND NOT TO ANY ACCESSORIES THE GATE PANEL ITSELF OR ANY GATE SUPPORT HARDWARE THIS WAR RANTY ONLY COVERS TH...

Reviews: