background image

21

Advance Controller Programming (Cont.)

Radio Enable

The controller contains a built in MegaCode® radio receiver to
allow  activation  from  up  to  40  access  control  transmitters  and
two  Model  MGT  (gate  edge)  transmitters.  The  factory  default
enables  the  internal  radio  receiver.  Alternately,  the  internal
receiver can be disabled.

NOTE:

  In  dual-unit  installations,  it  is  recommended  to  disable

the radio receiver in one of the two operators.

Antenna Installation

The controller is supplied with a local whip antenna installed. If
using  a  remote  antenna,  remove  the  wh ip  antenna  and
connect  coax  cable  from  the  antenna  to  the

ANTENNA

connector.

Radio Transmitter Learn

The  controller’s  built -in  MegaCode®  radio  receiver  can  store
the  IDs  of  up  to  40  transmitters.  Refer  to  the  figure  for  the
steps required to learn transmi tters.

NOTE:

  This  function  will  NOT  be  displayed  if  the  transmitter

memory is full, or if the radio receiver is disabled.

Radio Transmitter Delete

Transmitters  can  be  deleted  from  the  controller’s  memory
either  individually,  or  all  at  the  same  time.  Refer   to  the  figure
for the steps required to delete transmitters.

NOTE:

  This  function  will  NOT  be  displayed  if  the  transmitter

memory is full, or if the radio receiver is disabled.

MGT Obstacle Transmitter Learn

The  controller  supports  one  or  two  Model  MGT  Obstacle
Transmitters. The transmitters can be programmed to function
as  Open  Obstruction,  Close  Obstruction,  Reverse,  or  Stop.
Refer to the figure for the steps required to learn MGT

NOTE:

This function will NO T be displayed if two MGT transmitters are
already stored in memory, or if the radio receiver is disabled.

MGT Obstacle Transmitter Delete

MGT transmitters can be deleted from the controller’s memory
either  individually,  or  all  at  the  same  time.  Refer  to the  figure
for the steps required to delete MGT transmitters.

NOTE:

  This  function  will  NOT  be  displayed  if  two  MGT

transmitters  are  already  stored  in  memory,  or  if  the  radio
receiver is disabled.

Reset Controller to Factory Defaults

The  controller  can  be

reset  with  this  function.

ALL

PROGRAMMED  DATA  WILL  BE  LOST,

and  the  factory

defaults  will  be  loaded.  This  function  will  not  erase  radio
transmitters.  Transmitters  must  be  deleted  with  the  two
functions above.

DO NOT RESET CONTROLLER WITHOUT

CONSULTING TECHNICAL SUPPORT AT 877 -331-4747.

FUNCTION

“CL”

ENTER

WHILE “CL” IS DISPLAYED, PRESS ENTER

ALL PROGRAMMED DATA WILL BE
CLEARED AND THE FACTORY DEFAULTS
WILL BE STORED IN MEMORY.

NOTE: THIS FUNCTION WILL NOT ERASE
TRANSMITTERS

RESET TO

FACTORY

FUNCTION

“RA”

OPTION

PRESS UP OR DOWN TO

CYCLE THROUGH

OPTIONS

PRESS ENTER TO

SELECT AN OPTION

INTERNAL RADIO RECEIVER DISABLED

INTERNAL RADIO RECEIVER ENABLED

RADIO

ENABLE

PRESS ENTER, “ML” WILL BLINK FOR 30 SECONDS WHILE THE
CONTROLLER IS READY TO LEARN AN MGT TRANSMITTER

ACTIVATE THE MGT TRANSMITTER, THE DISPLAY WILL
SHOW”_ _” THEN THE TRANSMITTER ID NUMBER – IF THE
TRANSMITTER IS ALREADY ENTERED “DU” WILL BE
DISPLAYED, IF DECODE IS BAD “ERROR” WILL BE DISPLAYED

PRESS ENTER, THE DISPLAY SHOWS DEFAULT MGT
TRANSMITTER FUNCTION (CLOSE OBSTRUCTION)

PRESS UP OR DOWN TO SELECT MGT FUNCTION:
“rE”   = REVERSE
“St”   = STOP
“OP” = OPEN OBSTRUCTION
“CL”  = CLOSE OBSTRUCTION

PRESS ENTER TO STORE OPTION, REPEAT STEPS FOR SECOND
MGT TRANSMITTER IF USED

ENTER

ENTER

ENTER

   UP

OR

DOWN

FUNCTION

“ML”

LEARNING MGT

TRANSMITTERS

ENTER

ENTER

ENTER

  UP

     OR

DOWN

FUNCTION

DELETING

TRANSMITTERS

“TD”

PRESS ENTER

“TD” WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER IS
READY TO DELETE ONE OR MORE TRANSMITTERS, (TO EXIT
WITHOUT DELETING ANY, PRESS ENTER)

TO DELET ALL TRANSMITTERS, PRESS ENTER FOR 2 SECONDS,
OR TO PICK TRANSMITTERS GO TO NEXT STEP

PRESS UP OR DOWN TO SCROLL THROUGH THE LIST OF
TRANSMITTER ED NUMBERS

THE TRANSMITTER ID NUMBER IS DISPLAYED (TO EXIT
WITHOUT DELETING, PRESS ENT ER) (TO PICK A DIFFERENT
TRANSMITTER ID, PRESS UP OR DOWN

PRESS ENTER FOR 2 SECONDS TO DELETE THE TRANSMITTER
DISPLAYED

PRESS ENTER

“MD” WILL BLINK FOR 30 SECONDS WHILE THE CONTROLLER IS
READY TO DELETE ONE OR MORE MGT TRANSMITTERS. (TO EXIT
WITHOUT DELETING ANY, PRESS ENTER)

TO DELETE ALL MGT TRANSMITTERS, PRESS ENTER FOR 2
SECONDS, OR TO PICK TRANSMITTER GO TO NEXT STEP

PRESS UP OR DOWN TO SCROLL THROUGH THE LIST OF MGT
TRANSMITTER ID NUMBERS

THE MGT TRANSMITTER ID NUMBER IS DISPLAYED (TO EXIT
WITHOUT DELETING, PRESS ENTER) (TO PICK THE OTHER
TRANSMITTER ID, PRESS UP OR DOWN) PRESS ENTER FOR 2
SECONDS TO DELETE THE MGT TRANSMITTER DISPLAYED

ENTER

ENTER

ENTER

     UP

OR

DOWN

ERASING MGT

TRANSMITTERS

E

FUNCTION

E

”MD”

Summary of Contents for SL-1000 R

Page 1: ...1 SL 1000 R RESIDENTIAL LIGHT COMMERCIAL SLIDE GATE OPERATOR MADE IN U S A ROTARY GATE SYSTEMS INC ALL RIGHTS RESERVED 2008 REV 1 1 1 877 331 4RGS 4747...

Page 2: ...t reversing Sensor Easy troubleshooting with easy to interpret LED display 200 cycles per day when used on properly installed gates Input for non contact secondary entrapment protection device In addi...

Page 3: ...t setup Stagger mode Stagger delay time Auxiliary relay mode Reverse delay time Low power mode Power failure mode Soft start stop duration Reset cycle count Maintenance alert trigger Mid travel stop p...

Page 4: ...ecurity personnel Approved Obstruction Detection Devices The following contact or non contact obstruction detection devices have been approved for use with this slide gate operator as part of a UL325...

Page 5: ...or installation A good earth ground is necessary to allow the controller s built in surge and lightning protection circuitry to work effectively All ROTARY GATE SYSTEMS gate operators are supplied wit...

Page 6: ...ety devices have been included in the layout of the system o A separate pedestrian gate has been included in the gate layout in a location safe from contact with the vehicular gate when it is in the f...

Page 7: ...7 Access Control Devices The SL 1000 R is compatible with any type of access control device which provides a dry contact relay for activation Installation Figure 2 Gate and Post Layout...

Page 8: ...8 Figure 3...

Page 9: ...st 7 Using a 5 16 drill drill a hole into the post through each of the four holes in the mounting plate Tap the holes using a 3 8 16 tap This step may be eliminated if welding the mounting plate to th...

Page 10: ...ontrol panel Secure the operator motor wire so as to ensure that it will stay c lear of the pinion gear rack gear and gate panel when in motion If necessary the motor wires from the operator can be ad...

Page 11: ...UT TERMINALS SINGLE INPUT TERMINALS PRIMARY SECONDARY COMM LINK TERMINALS FIRE DEPT INPUT TERMINALS ACCESSORY POWER TERMINALS DISPLAY PROGRAMMING BUTTONS INPUT POWER TERMINALS PLUG IN LOOP DETECTOR CO...

Page 12: ...OR CURRENT HAS EXCEEDED THE OPEN CURRENT SETTING WHILE OPENING SET MAXIMUM OPEN CURRENT OPEN OBSTR MGT 2 SET OPEN OBSTRUCTION TERMINAL CONNECTED TO COMMON BY BEAM OR SAFETY EDGE OR SIGNAL FROM MGT OBS...

Page 13: ...HEN STOP AGAIN AT THIS TIME THE AUTO CLOSE TIMER IS DISABLED AND A RENEWED INPUT WILL BE REQUIRED TO START THE GATE AGAIN SHOULD THE GATE BE RESTARTED AND THE OBSTACLE SIGNAL OCCUR AGAIN PRIOR TO REAC...

Page 14: ...CH PHOTOEYE FOR CLOSE OBSTRUCTION FIRE ACCESS SWITCH SOLENOID LOCK EXTERNAl POWER PHOTOEYE FOR OPEN OBSTRUCTION SINGLE CHANNEL RADIO RECEIVER MAGLOCK GATE EDGE SENSOR FOR REVERSE TWO CHANNEL RADIO REC...

Page 15: ...T 110 VAC 110 VAC WIRES ARE UNDER TRANSFORMER MOTOR Connect motor wires from SL 1000 R gate operator LIMIT SWITCHES Connect to the wires from the limit switches Black wires go to COMMON RED to OPEN or...

Page 16: ...f the gate For left hand installations program the controller for left hand operation WHEN CHANGING TO LEFT HAND OPERATION YOU MUST ALSO REVERSE THE MOTOR LEADS IN ADDITION Dual Gate Enable The factor...

Page 17: ...If the close current load exceeds the programmed maximum load number the operator will stop reverse a short distance then stop again If after restart the overload or a close obstacle happens again be...

Page 18: ...o ne operator for delayed opening and the other operator for delayed closing The Stagger Delay Time programming function see below sets the length of the delay NOTE This function will only be displaye...

Page 19: ...is set for Open Immediate alternately the controller can be set for Fail Secure Open Immediate or Close Immediate Fail Safe If the AC power fails and the battery voltage drops below 17 volts 5 second...

Page 20: ...med to open for 1 to 99 seconds the stop before reaching the open limit When a Mid travel stop position time has been programmed the gate will still fully open if the Fire Department input is triggere...

Page 21: ...s function will not erase radio transmitters Transmitters must be deleted with the two functions above DO NOT RESET CONTROLLER WITHOUT CONSULTING TECHNICAL SUPPORT AT 877 331 4747 FUNCTION CL ENTER WH...

Page 22: ...osing at any time Single Input Opens the gate if it s closed and closes th e gate if it s open open close programming option Activating the input while the gate is moving will reverse the gate Can be...

Page 23: ...run alarm will beep twice as fast and continue for five minutes after the gate stops The sounder will chirp every five seconds when the gate is idle Correct the trouble close case replace battery or...

Page 24: ...ndicated by EN 04 on the APeX display To clear this error press the RESET button on the out side of the control box and give the system an OPEN or CLOSE signal Model SL 1000 R Maintenance Battery Main...

Page 25: ...in your area THIS WARRANTY APPLIES ONLY TO THIS PRODUCT WHEN INSTALLED BY A QUALIFIED DEALER AND NOT TO ANY ACCESSORIES THE GATE PANEL ITSELF OR ANY GATE SUPPORT HARDWARE THIS WAR RANTY ONLY COVERS TH...

Reviews: