13
Terminal Descriptions
TERMINAL
GROUP
FUNCTION
AC N
AC
24 VOLT INPUT
FACTORY CONNECTED TO 24 VAC FROM TRANSFORMER OR
24 VDC FROM CONTINUOUS DUTY DC SUPPLY.
DC
-
DC
+
ACCESSORY POWER PROVIDES 24 VOLT DC POWER FOR ACCESSORIES.
RESET
COMMON
RESET BUTTON
FACTORY CONNECTED TO THE CONTROLLER’S RESET BUTTON.
C
B
A
COMM LINK
FOR 3-WIRE NETWORK CONNECTION TO SECOND OPERATOR IN DUAL GATE INSTALLATIONS.
COMMON
SINGLE
SINGLE BUTTON
INPUT
CONNECT TO NORMALLY OPEN SWITCH FOR SINGLE BUTTON OPERATION. ALTERNATES
BETWEEN OPEN-CLOSE OR OPEN-STOP-CLOSE DEPENDING ON PROGRAMMING.
COMMON
FIRE DEPT
FIRE BOX INPUT
CONNECT TO NORMALLY OPEN SWITCH IN FIRE BOX FOR FIRE DEPARTMENT ACCESS.
COMMON
OPEN
OPEN INPUT
CONNECT TO NORMALLY OPEN DEVICES (KEYPAD, CARD READER, KEYSWITCH, TELEPHONE
ENTRY SYSTEM) TO OPEN THE GATE. A CONSTANT OPEN INPUT WILL OVERRIDE THE MID-
TRAVEL STOP AND HALT THE AUTO CLOSE TIMER UNTIL RELEASED.
OPEN
CLOSE
COMMON
STOP
3-BUTTON
STATION
INPUT
CONNECT TO 3-BUTTON STATION FOR OPEN-CLOSE-STOP CONTROL. A CONSTANT OPEN INPUT WILL
OVERRIDE THE MID-TRAVEL STOP AND HALT THE AUTO CLOSE TIMER UNTIL RELEASED.
COM
O-OBS
CONNECT TO NORMALLY OPEN DEVICES (GATE EDGE, PHOTO BEAM) TO DETECT AN
OBSTRUCTION DURING OPENING. WHILE GATE IS IN MOTION, ANY OPEN OBSTRUCTION
SIGNAL WILL CAUSE THE GATE TO STOP, REVERSE A SHORT DISTANCE, AND THEN
STOP AGAIN. AT THIS TIME THE AUTO CLOSE TIMER IS DISABLED AND A RENEWED INPUT
WILL BE REQUIRED TO START THE GATE AGAIN. SHOULD THE GATE BE RESTARTED AND
THE OBSTACLE SIGNAL OCCUR AGAIN PRIOR TO REACHING A LIMIT, THE GATE WILL STOP
AGAIN, LOCKOUT, AND SOUND THE EMERGENCY ALARM.
C-OBS
COM
OBSTRUCTION
INPUTS
FUNCTIONS THE SAME AS THE OPEN OBSTRUCTION, EXCEPT IN THE CLOSING DIRECTION.
COM
REV
REVERSE
CONNECT TO NORMALLY OPEN DEVICES TO CAUSE A REVERSAL WHEN THE GATE IS
TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL OPEN POSITION.
OPEN LOOP
OPEN LOOP
OPEN LOOP
CONNECT TO OPEN LOOP/FREE EXIT LOOP. THE GATE WILL OPEN WHEN THE LOOP
IS TRIGGERED, AND REMAIN OPEN AS LONG AS THE LOOP IS TRIGGERED
REVERSE LOOP
REVERSE LOOP
REVERSE LOOP
CONNECT TO REVERSE LOOP. TRIGGERING THE LOOP WILL CAUSE A REVERSAL WHEN THE GATE
IS TRAVELING CLOSED. THE GATE WILL REVERSE TO THE FULL OPEN POSITION.
SHADOW/RESET
LOOP
SHADOW/RESET
LOOP
SHADOW/RESET
LOOP
CONNECT TO SHADOW/RESET LOOP TO KEEP THE GATE IN ITS FULLY OPEN POSITION AS LONG
AS THE SIGNAL IS PRESENT. USED TO KEEP GATE OPEN WHILE VEHICLE IS PASSING THROUGH.
-
+
ALARM
FACTORY CONNECTED TO THE ALARM BEEPER.
N.O.
COM
N.C.
AUX RELAY
FOR CONNECTION TO AUXILIARY DEVICES (MAGNETIC LOCK, SOLENOID LOCK, STROBE
LIGHT) FOR ACTIVATION (OR DEACTIVATION) DURING GATE OPERATION.
ON THE SL-
1000
i
, THIS RELAY IS USED TO RELEASE THE INTERNAL BRAKE.
+
-
24 VOLT SOLAR
PANEL
FOR CONNECTION TO 24 VOLT SOLAR PANEL FOR BATTERY CHARGING.
+
-
24 VOLT BATTERY
FACTORY CONNECTED TO BATTERIES IN DC MODEL OPERATORS.