Advanced Controller Programming (Cont.)
Auxiliary Relay Mode
The Auxiliary Relay in the SL -1000 R is not used to release the
magnetic brake inside the operator as in the other RGS
operators. The auxiliary relay has normally open and normally
closed contacts. The factory setting disables the Auxiliary
Relay. The relay can be set for:
Maglock:
The relay will energize during any pending of
actual gate motion (open only), to deactivate a
magnetic or solenoid gate lock.
Ticket Dispenser:
The relay will energize while the
gate is moving in the open direction and at the full
open limit, or in an entrapment condition.
Strobe:
the relay will energize during any pending or
actual gate motion (either open or close), to activate a
warning strobe light.
Alarm:
The relay will energize if the gate is manually
forced open from the full closed position.
Reverse Delay Time
The factory default sets the Reverse Delay to 1 second. The
operator will wait the length of the delay before reversing
direction. This feature will not change the reversal time when
the operator is responding to an entrapment condition from an
obstruction input or inherent entrapment protection sensor. The
Reverse Delay can be set from 1 to 9 seconds. Heaver gates
require a longer delay to allow time for the gate to stop.
Low Power Mode
The factory default disables the Low Power Mode. When Low
Power Mode is enabled, and AC power fails, the controller will
assume Low Power Mode after 10 seconds of gate inactivity.
Low Power Mode turns off all accessory power and indicators.
Only inputs from the radio receiver, reverse loop or opening
device will activate gate.
Power Failure Mode
The factory default is set for
Open Immediate
; alternately the
controller can be set for Fail Secure, Open Immediate, or
Close Immediate.
Fail Safe:
If the AC power fails and the battery voltage drops
below 17 volts, 5 seconds later the operator will cycle
open if not already open and cease operation. When AC
power is restored, the operator will resume normal
operation and auto-close if programmed to do so.
Fail Secure:
If the AC power fails and the battery voltage
drops below 17 volts, 5 seconds later the operator will
cycle closed if not already closed. When AC power is
restored, or the battery gets charged by solar panels, the
operator will resume n ormal operation.
Open Immediate:
If the AC power fails, the operator will
cycle open if not already open and cease operation.
When AC power is restored, the operator will resume
normal operation and auto -close if programmed to do so.
Close Immediate:
If the AC power fails, the operator will
cycle closed if not already closed and cease operation.
When AC power is restored, the operator will resume
normal operation.
FUNCTION
“AR”
AUXILIARY RELAY DISABLED
AUZILIARY RELAY USED FOR MAGLOCK
CONTROL
AUXILIARY RELAY USED FOR TICKET
DISPANSER CONTROL
AUXILIARY RELAY USED FOR WARNING
STROBE LIGHT
AUXILIARY RELAY USED FOR CONNECTION
TO ALARM DEVICE
PRESS UP OR DOWN
TO CYCLE THROUGH
OPTIONS
PRESS ENTER TO
SELECT AN OPTION
AUXILIARY
RELAY MODE
OPTIONS
“RD”
SET TIMER VALUE
1 TO 9 SECONDS
FUNCTION
OPTIONS
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
REVERSE
DELAY TIME
“FS”
FUNCTION
SET TO FAIL SAFE MODE
SET TO FAIL SECURE MODE
SET TO OPEN IMMEDIATE MODE
SET TO CLOSE IMMEDIATE
MODE
PRESS UP OR DOWN
TO CYCLE THROUGH
OPTIONS
PRESS ENTER TO
SELECT AN OPTION
POWER
FAILURE MODE
LOW POWER MODE
DISBLED
“LP”
FUNCTIONS
OPTIONS
PRESS UP OR DOWN
TO CYCLE THROUGH
OPTIONS
PRESS ENTER TO
SELECT AN OPTION
LOW POWER
MODE