Quick Reference Guide for Auxiliary Mode Setting
Auxiliary
Mode
Auxiliary Input
Function
Auxiliary Output
Activated by
Auxiliary
Relay
Auxiliary Settings
(in seconds)
0
AUX REX
Valid code or AUX REX
N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle
1
Normal/Secure switch Valid code
N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle
2
Normal/Secure switch Star button (
)
N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle
3
Normal/Secure switch Tamper event
N.C. 01 to 99 Aux. relay release time
00 Aux. relay tamper activated
4
Normal/Secure switch Direct shunt
N.O. 01 to 99 Shunt time
5
Door Monitor
Shunt
N.C. 01 to 99 Maximum shunt time
6
Door Monitor
Forced door
N.C. 01 to 99 Forced delay
7
Door Monitor
Door ajar
N.C. 01 to 99 Ajar delay
8
LED control – Green Valid code
N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle
9
LED control - Red
Valid code
N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle