Description
Command
Toggles the GPI output signal to the
opposite level. If the level GPI is
currently set to high (5V), toggle sets
the GPI to low (0V). Toggle always sets
the level to the opposite of what it
currently is, regardless of the trigger
level. Toggle GPI does not apply to
pulse GPIs.
1.
Press GPO.
2.
Use the GPO Function knob to
select GPO Toggle.
3.
Use the GPI Output knob to
select the GPI output you want to
apply the function to.
GPO Toggle
Sets the GPI output to the trigger level.
For a level high GPI (5V) trigger sets
the GPI to high (5V), even if the GPI is
already triggered and at high (5V).
Trigger applies to both level and pulse
GPIs.
1.
Press GPO.
2.
Use the GPO Function knob to
select GPO Trigger.
3.
Use the GPI Output knob to
select the GPI output you want to
apply the function to.
GPO Trigger
Memories
Press
Insert Event
>
Special
.
Description
Command
Recall a specific memory on one or
more MEs.
1.
Press the ME X for the MEs that
you want the memory to be
recalled on.
2.
Use the Memory knob to select
the memory you want to recall.
Memory Recall
Menus
Press
Insert Event
>
Special
.
Description
Command
Navigate to a particular menu. This
allows you to quickly jump between
frequently used menus without having
to navigate through the menu system.
Go To Menu
Monitor Wall
Press
Insert Event
>
More
>
Monitor Wall
.
Description
Command
Assign a specific input channel to a
particular box on the Monitor Wall.
Each box in a layout requires an input
channel for the video it displays.
Assign Chan
Load a specific layout on a monitor
wall. A monitor wall can have several
different layouts created, each with a
variety of monitors and inputs.
Load Layout
Assign specific, pre-defined, Dynamic
text to a particular text address on a
monitor wall layout. The text address
will have to be assigned to a template
for a custom control event to be able
to change the text. There are two
types of text labels used on a monitor
wall.
•
Static Text — set during the
creation of the monitor wall setup
and can only be modified using the
tools provided with the monitor
wall.
•
Dynamic Text — modified at any
time from the switcher.
Modify Text
OverDrive
®
Press
Insert Event
>
Special
.
Description
Command
Send the command to OverDrive
®
to
run one of the custom controls in
rundown control.
•
Use the CC knob to select the
custom control you want to run.
OverDrive:
On-Air CC
Send the command to OverDrive
®
to
run one of the prepared custom
controls in rundown control.
•
Use the CC knob to select the
custom control you want to run.
OverDrive: Prep
CC
Send the command to OverDrive
®
to
prepare the next shot in the rundown.
OverDrive: Prep
Next
Send the command to OverDrive
®
to
prepare the previous shot in the
rundown.
OverDrive: Prep
Prev
Send the command to OverDrive
®
to
run a selected event in a rundown.
•
Use the Cmd knob to select the
command.
OverDrive:
Rundown
Send the command to OverDrive
®
to
take the current shot on-air and
prepare the next shot in the rundown.
OverDrive: Take
& Prep
Ultrix Acuity Operation Manual (v10.1) — Custom Controls • 77