Description
Command
Take the current effect in the sequence
on-air.
Seq Take
Set the default folder for pages or
templates.
Set Folder
Take the current effect off-air with a
transition. Click Change Template and
enter a specific template to take
off-air.
Take Offline
Play the next effect that is cued up on
the Character Generator. The next
effect will be on the preview (PV) of
the Character Generator and will be
taken to the program (PGM) of the
Character Generator with this event.
Take
Send a trigger command to the
Character Generator.
Trigger
DVE
Press
Insert Event
>
DVE
.
Description
Command
Advance the DVE effect forward by one
frame.
Frame Advance
Reverse the DVE effect forward by one
frame.
Frame Reverse
Cue the DVE to the end of the effect.
Go To End
Cue the DVE to the start of the effect.
Go To Start
Cue the DVE effect to the next
keyframe boundary.
Key Frame
Advance
Cue the DVE effect to the previous
keyframe boundary.
Key Frame
Reverse
Send the pause command to the DVE.
Pause
Send the play command to the DVE.
Play
Send the play in reverse command to
the DVE.
Play Rev
Recall an effect on the DVE (from 1 to
99).
Recall
Send the rewind command to the DVE
(simulated a shuttle reverse).
Rewind
Send the stop command to the DVE.
Stop
GPI/Tallies
Press
Insert Event
>
More
>
More
>
GPO/Tally
.
Description
Command
Manually opens or closes the selected
panel tally.
1.
Use the Open/Close knob to
select whether the tally will be set
open or closed.
2.
Use the Tally knob to select the
panel tally that you want to set as
open or closed.
Panel Tallies
Manually opens or closes the selected
frame tally.
1.
Use the Open/Close knob to
select whether the tally will be set
open or closed.
2.
Use the Tally knob to select the
frame tally that you want to set
as open or closed.
Frame Tallies
Manually opens or closes the selected
contact closure.
1.
Use the Open/Close knob to
select whether the contact
closure will be set open or closed.
2.
Use the Contact Closure knob to
select the contact closure that
you want to set as open or closed.
Contact Closure
Returns the GPI output signal to the
base level. For a level high GPI (5V)
reset sets the GPI to low (0V), and for
a level low GPI (0V) reset sets the GPI
to high (5V). Reset GPI does not apply
to pulse GPIs.
1.
Press GPO.
2.
Use the GPO Function knob to
select GPO Reset.
3.
Use the GPI Output knob to
select the GPI output you want to
apply the function to.
GPO Reset
Manually trigger a GPI input on the
switcher. The switcher reacts as if a
trigger was received on the selected
input GPI. Simulate applies to both
level and pulse GPIs.
1.
Press GPO.
2.
Use the GPO Function knob to
select GPO Simulate.
3.
Use the GPI Input knob to select
the GPI input you want to apply
the function to.
GPO Simulate
76 • Custom Controls — Ultrix Acuity Operation Manual (v10.1)