5.
In the
Restrict to Folder
area, select if you want to restrict remote control of the selected room to
only seeing the contents of a specific folder, or all folders (
All Folders
).
6.
In the
Response Time
area, select how quickly the server executes the Clip Play command after the
Clip Load command.
•
Fast
— executes the play command immediately after the load command. This is recommended
when controlling the server from an external switcher.
•
Accurate
— executes the play command only after receiving confirmation that the clip has loaded.
This is recommended when controlling the server from an automation system.
7.
In the
Channel Control Port
area, select whether you want to use the serial ports or ethernet
connection for the channels assigned to the room.
8.
In the
Edit Timing
area, select a timing offset for when you are controlling the server from an external
editor over serial.
•
Timecode Alignment
— select the offset, in frames, of the timecode information that is sent to
the editor during playout or record.
•
Source Alignment
— select the offset, in frames, of the timecode information that is sent to the
editor during playout.
•
Out Point Offset
— select the offset, in fields, of the out-point timecode value that is sent to the
editor during record.
9.
In the
Video Edit Effect
area, select which tracks get recorded when an external editor issues the
Video Record command to the server.
•
Edit Video Track
— only the video track is recorded.
•
Edit Key Track
— only the alpha (key) track is recorded.
•
Edit Video and Key Tracks
— both the video and alpha (key) tracks are recorded. The clip loaded
into the VKA channel transport must have an alpha track.
10.
In the
VDCP Configuration
area, select specific configurations for the protocol you are using.
• Select
Louth Preview
to allow clips to be pre-cued in the background for seamless back-to-back
transitions during playout.
• Select
Allow playlists control
to allow a playlist to be cued and played from an external device
just like a clip.
• In the
Maximum length of Clip Name
field, select the maximum length of a clip name that is
reported to the controlling device.
11.
Click on the
Ch-X:
list and select the room and port that you want to assign to the channel.
•
Room
— assign the room configuration to the channel transport you want to control.
•
RS422 Port
— select the RS-422 serial port that you want to use to control the channel transport
or select
No RS422 port
for ethernet.
Important:
There are only two (2) RS422 ports on the server. To control all four channel transports remotely you must
select an ethernet protocol.
12.
Click
Restart Tria
. A confirmation dialog box is displayed.
13.
Click
Restart Tria
to restart the server application and services with the new setting.
14.
Click
OK
when the restart has completed to dismiss the window.
To Configure a Room for the AMP Protocol
Set up a Room to use the AMP protocol to control server channels.
Note:
When controlling the server from a remote device over ethernet, you must select the port as 3811 and then select the channel you
want to send the commands to.
1.
Launch the Tria Config application.
74 • Remote Control Support — Tria Express DUET User Manual (v01)