3.
Click
Room X Configuration
and select the room you want to configure. Later you will assign this
room to a channel.
4.
In the
RS422 Protocol
area, select
Odetics
.
5.
In the
Response Time
area, select how quickly the server executes the Clip Play command after the
Clip Load command.
•
Fast
— executes the play command immediately after the load command. This is recommended
when controlling the server from an external switcher.
•
Accurate
— executes the play command only after receiving confirmation that the clip has loaded.
This is recommended when controlling the server from an automation system.
6.
In the
Edit Timing
area, select a timing offset for when you are controlling the server from an external
editor over serial.
•
Timecode Alignment
— select the offset, in frames, of the timecode information that is sent to
the editor during playout or record.
•
Source Alignment
— select the offset, in frames, of the timecode information that is sent to the
editor during playout.
•
Out Point Offset
— select the offset, in fields, of the out-point timecode value that is sent to the
editor during record.
7.
In the
Video Edit Effect
area, select which tracks get recorded when an external editor issues the
Video Record command to the server.
•
Edit Video Track
— only the video track is recorded.
•
Edit Key Track
— only the alpha (key) track is recorded.
•
Edit Video and Key Tracks
— both the video and alpha (key) tracks are recorded. The clip loaded
into the VKA channel transport must have an alpha track.
8.
In the
Odetics Protocol Configuration
area, select specific configurations for the protocol you are
using.
• Select
Disable field timecode reporting
to force the server to report timecode only once every
video frame. If this option is not selected, the server reports timecode every field.
72 • Remote Control Support — Tria Express DUET User Manual (v01)