Bank A-E: Factory Defaults
This function allows you to return all controls to their default values, or simply the six “Proc Amp”
controls by themselves. Use the following steps to select factory default values:
1. Select Bank A, and rotate
Function Select
to position E.
2. Select the desired default settings:
•
Hold
Mode Select
up to reset all adjustments to their default values.
•
Hold
Mode Select
down to reset the six “Proc Amp” adjustments to their
default values (
Video Gain
,
Black Level Offset
,
Chroma Gain
,
Hue
,
C
B
Gain
, and
Chroma AGC
).
Bank SW1 Function Select SW2 Mode Select Heads-Up Display Label
Default
A
E
+ (h)
Reset All
- (h)
Reset Proc Amp
DEFAULT ALL RST
PROC RST
N/A
Bank A-F: Lock/Unlock Switch Access
The
Switch Access
function allows you to lock or unlock user access to all adjustment parameters.
The “lock” function should be performed after installation to secure all settings, and to prevent anyone
from accidentally changing the settings. Note the following rules:
•
When access is locked, no adjustments can be made and the Heads-Up Display is
automatically turned off.
•
When you unlock switch access and you wish to use the Heads-Up display again,
you must manually enable it (Bank A, Position 1).
Use the following steps to lock or unlock switch access:
1. Select Bank A, and rotate
Function Select
to position F.
2. Choose the desired access mode:
•
Toggle
Mode Select
up
to lock switch access. Adjustments cannot be
made, and the display is disabled. The
ACCESS
LED is off.
•
Hold
Mode Select
down
for one second to unlock switch access.
Adjustments can now be made. The
ACCESS
LED is on.
Bank SW1 Function Select SW2 Mode Select Heads-Up Display Label Default
A
F
+ Locked
- (h) Unlocked
ACCESS LOCKED
UNLOCKED
LOCKED
4-10
•
Using Banks
ADC-8032A User Manual (Iss. 04)