Bank A, B, and C Function Tables
This section presents a detailed charting of all board-level ADC-8032A functions in the following
three tables. The operational usage is explained in the next section.
Table 3. Function Select: Bank A Function Table
SW1
Function
Select
Function
SW2 Mode Select
Options
Heads Up Display
On-Screen Label and
Value
Default
Value
0 Bank
Select
+ A
B
- C
BANK A
B
C
A
1 Heads-Up
Display
+ (h) On
- Off
HEADS UP
ON
OFF
OFF
2 N/A
3 N/A
4 N/A
5 N/A
6 N/A
7 N/A
8 Video
Gain
m
+ Increase
- Decrease
VID GAIN (###.#)%
100% *
9
Black Level Offset
m
+ Increase
- Decrease
BLK OFF (##.#) IRE
0 IRE *
A Chroma
Gain
m
+ Increase
- Decrease
CHROMA (###.#)%
100% *
B Hue
m
+ Increase
- Decrease
HUE
(###.#) DEG.
0 DEG. *
C C
B
Gain
m
+ Increase
- Decrease
C
B
GAIN (###.#)%
100% *
D Chroma
AGC
+ On
- Off
CHROMA AGC ON
OFF
OFF *
E Factory
Defaults
+ (h) Reset All
- (h) Reset Proc Amp
DEFAULT ALL RST
PROC RST
N/A
F
Switch Access **
+ Locked
- (h) Unlocked
ACCESS LOCKED
UNLOCKED
LOCKED
Note:
Functions, as listed in the Function
column as being stored in memory, always power up in the
last known state. All other items, however, power up in the default state, regardless of their previous
state.
* Indicates Proc Amp controls that are affected by position E, Factory Defaults
function.
** Locking Switch Access shuts off the Heads-up Display. Unlocking will not restore
the display if it was previously enabled. This must be performed manually.
m
Stored in memory
ADC-8032A User Manual (Iss. 04)
Using Banks
•
4-3