1.
No display -
Adjustments are made using the
Function Select
and
Mode Select
switches, without the assistance of the Heads-Up Display or the Comlink
Display. Results should be confirmed with test equipment suitable for
measuring the parameter being adjusted (such as a waveform monitor or vector
scope).
2.
Heads-Up Display -
Adjustments are made using
Function Select
and
Mode
Select
switches
in conjunction with the Heads-Up Display. Ensure that the
Heads-Up Display is enabled (Bank A, Position 1). Note that the display is
superimposed over
all
ADC-8032A video outputs.
3.
Terminal Display -
Adjustments are made using
Function Select
and
Mode
Select
switches
in conjunction with the Comlink Display. Ensure that the
Comlink port is properly connected to a PC. Refer to Chapter 8, “
Comlink
”
for instructions.
Note
Both the
Heads-Up Display
and the
Comlink Display
can be used
simultaneously.
Operating Conventions For Function Tables
The following rules apply to the function tables that are used throughout this section:
•
The label “
+
”
instructs you to toggle the
Mode Select
switch
(SW2)
up
momentarily.
•
The label “
-
” instructs you to toggle the
Mode Select
switch
(SW2)
down
momentarily.
•
The label “
+
(h)
” instructs you to
hold
the
Mode Select
switch
(SW2)
up
for one
second.
•
The label “
-
(h)
” instructs you to
hold
the
Mode Select
switch
(SW2)
down
for one
second.
Selecting Banks
Function Select
switch functionality is divided into three banks of functions. Use the following steps
to select Bank
A
,
B
or
C
as required.
1. Rotate
Function Select
(SW1)
to position 0. Note that position 0 is always used to
select the bank, regardless of the bank that you are currently using.
2. Toggle
Mode Select (SW2)
up or down to choose the desired bank. Three positions
are available: Bank A, B or C.
3. The table below illustrates each switch function, along with the Heads-Up Display
label, the Status LED indication, and the default value. If you are not using a
display, be sure to verify your selection on the Status LED's.
Table 2. Switch and Bank Selection
Mode Select SW2
Heads-up Display Label
Status LED
Default Bank
+
A
BANK A
BANK A
A
B
BANK B
BANK B
A
-
C
BANK C
BANK C
A
4-2
•
Using Banks
ADC-8032A User Manual (Iss. 04)