SLF 2250/4000
Hydromatic Stinger
Page - 87 -
© 2014
- Connect a hose to connection (J42) and open valve (J41) until
clear water is discharged.
- Flush the foam compound suction line:
◊
Press switch (S326) -> screen (ACRe) will be shown on display (N7).
◊
Preselect the external foam compound container by using
switch (SF4).
◊
Open the foam suction valve by pressing switch (S319) and open
valve (J46).
◊
Continue to flush until clean water flows out of connection
(J47).
◊
Press again switch (S319).
- Open flushing valves (J164/2) for the foam-side pressure gauges.
- Close the internal flushing valve:
◊
Call up the maintenance menu (MM) and press again switch
(SF1).
- Disengage the foam compound pump as mentioned in the
"Engaging the Hydraulic Oil Pumps" chapter.
bar
Hydromatik
Hydromatik
N7
SF2
SF1
S348
Fremdsaugen
2
Push
Hydromatic
To turn on
AUTO
MANU
Tank 1
3/4
1/2
1/4
ACRe
SF4
S326
Maintenance
J42
J47
J46
J41
J164/2