Maintenance
Starting Aid (Jump Starting)
ATTENTION !
Jump starting is allowed only with a 24
voltage battery-package in direct con-
nection (jumper cables)!
Before disconnecting the jumper ca-
bles engage a large current consumer
(e.g. heating system) on the "giver vehi-
cle" in order to dampen voltage spikes.
Never attempt to start the vehicle with
a quick charger - this will surely result
in damage to the electrical system.
Service procedures - Battery
If your vehicle is equipped with a battery charging socket, it is
possible to charge the batteries by means of a positively polarized
plug without dismounting the batteries.
Precondition:
Use only electronically controlled charging units.
ATTENTION !
To avoid damage to the alternator and radio installed in the
vehicle, it is absolutely necessary to switch off the main battery
switch only after the engine of the vehicle has been shut off.
Before connecting a battery charging unit to the charging socket,
please switch off the main battery switch. similarly switch it off
when the vehicle is stored in the garage.
Battery charge and acid-density in kg/dm
3
at 20
°
C:
Charge
Acid-density at battery gen.
Acid-density at tropic batt.
Action
Charged
1,28
1,23
none
1/2 charged
1,20
1,16
charge necessary
empty
1,12
1,08
charge immediately
Batteries, which show maintenance mistakes, are not replaced by the manufacturer.