Page - 104 -
© 2014
SLF 2250/4000
Hydromatic Stinger
Maintenance
Service procedures - Mounting devices for body, water- and foam
compound tank - sub frame / chassis
The sub frame is bolted fixedly to the chassis but bolted flexibly
in other areas by means of spring loaded elements.
The original pre-adjusted flexible element, see reading (x) must
not be changed or bolted to "block" condition under any circum-
stances.
During regular service and maintenance procedures these flexible
elements have to be checked for free movement, rust and to ensure
that the unit is not "stuck" in the area of the bolt and spring.
The "free movement" can turn into a "stuck" condition by soiling,
dirt, corrosion etc. and might cause damages to the body and
sub frame.
Remedy:
- Check flexible elements regularly according to the maintenance
manual.
- If necessary, dismantle the unit, clean and grease the parts or
change damaged items.
ATTENTION! Check pre-adjusted reading (x) before dismantling!
- Install unit and adjust to the correct (x) reading.
Use grease (Article No.: 004824) only