Page - 26 -
© 2014
SLF 2250/4000
Hydromatic Stinger
Technical Description
Display in driver´s cabin - switches and pilot lamps of fire fighting
superstructure in the cabin
N6
display
SF1
switch: function
SF2
switch: function
SF3
switch: function
SF4
switch: function
SF5
switch: function
S1
alarm switch: all rotating beacons on **
- the alarm signal sounds as long as the horn of the vehicle
is pressed *
S1/2
alarm switch: the "Martin" alarm signal starts operating
continuously - only active when switch (S1/1) is engaged
S2/2
switch: water pump ON / OFF
S26
switch: additional alarm lights on front grill
- only active with switch (S1/1) engaged **
S226 switch: rear view camera and maneuvering lights
S257 switch: close-illumination **
S317 switch: to voltage gauge menu
S318 switch: to working hour counter menu
S319 switch: enter button
S320 switch: return to main display **
S466 switch: to pump control menu **
**
by using this switch another menu will be shown on screen
- for further operation please use switch (SF1) to (SF5)
Note:
A diode is installed above each switch which illuminates when the
corresponding switch is engaged or a function is engaged belong-
ing to the sub-menu.
If another menu is required, the diode gives information that a
function is engaged in a corresponding sub-menu.
The description includes optional equipment which is possibly not
installed on your vehicle.
S257
S226
S466
S320
S317
S318
S1/1 S1/2 S26
N6
S319
SF1
SF3
SF4
SF5
SF2
S2/2