9-7
Rosemount Tank Radar Rex
Chapter 9 Technical Data
Service Manual
308012En, Ed.2
May 2013
9.7
DAU 2100
Ambient operating temperature
-40 °C to 65 °C (-40 °F to 149 °F)
Sensor elements
Pt 100 single or multispot
Number of sensor elements
Max. 14 per DAU
Temperature measuring range
Range 1: -50 °C to 125 °C (-58 °F to
257 °F)
Range 2: -50 °C to 300 °C (-58 °F to
572 °F)
Range 3: -200 °C to +150 °C (-330
°F to 302 °F)
Explosion protection
II 1G Ex ia IIB T4 Ga (ATEX) and
Class 1, Div I, Groups C and D
(UL913 USA).
Power Supply
Intrinsically safe supply from Radar
Tank Gauge.
Field bus
Intrinsically safe local line from
Radar Tank Gauge.