Rosemount Tank Radar Rex
Chapter 9 Technical Data
9-8
Service Manual
308012En, Ed.2
May 2013
9.8
RDU 40
Ambient temperature
-20 °C to +70 °C (-4 °F to +158 °F)
Hazardous locations
certifications
II 2 G Ex ib IIC T4 Gb
FM
Class I Div I Group A, B, C, D
Max cable length
100 m (328 ft) (total length if two units are con-
nected to the same gauge)
Cable requirement
3-wire, shielded instrument cable
Min 0.5 mm² (AWG 20)
Max 2.5 mm² (AWG 14)
Max Ø14 mm (0.55 inch)
Min insulation thickness for each wire 0.25 mm
(0.00985 inch)
Material housing
Die cast aluminium
Dimensions
150 x 120 x 70 mm (6 x 4 x 3 inch)
Weight
1.2 kg (2.6 lbs)
Ingress protection
IP 66 & 67