![Rosemount TankRadar Rex DAU 2100 Service Manual Download Page 26](http://html1.mh-extra.com/html/rosemount/tankradar-rex-dau-2100/tankradar-rex-dau-2100_service-manual_1487430026.webp)
Rosemount Tank Radar Rex
Chapter 3 Device Description
3-12
Service Manual
308012En, Ed.2
May 2013
Technical Data, Analog output
Type
Analog 4-20 mA current loop, passive
or active output (external or internal
loop supply)
Galvanic isolation
>1500 V RMS or DC
Range
4-20 mA
Alarm level
3.8 mA, 22 mA, “freeze current”, Binary
High or Binary Low; software select-
able
Resolution
0.5 mA (0.003%)
Linearity
± 0.01%
Temperature drift
± 50 ppm/C°
Output impedance
>10 MW
Voltage compliance
7-30 V
External loop resis-
tance
<700 W (passive output with 24 V
external supply).
<300 W (active output).
Summary of Contents for TankRadar Rex DAU 2100
Page 2: ......
Page 3: ...www rosemount tg com Service manual Second edition Copyright May 2013 Rosemount Tank Radar AB ...
Page 8: ...Rosemount TankRadar Rex Contents TOC 4 Service Manual 308012En Ed 2 May 2013 ...
Page 116: ...Rosemount Tank Radar Rex Chapter 4 Service 4 72 Service Manual 308012En Ed 2 May 2013 ...
Page 124: ...Rosemount Tank Radar Rex Chapter 5 Calibration 5 8 Service Manual 308012En Ed 2 May 2013 ...
Page 132: ...Rosemount Tank Radar Rex Chapter 6 Troubleshooting 6 8 Service Manual 308012En Ed 2 May 2013 ...
Page 134: ...Rosemount Tank Radar Rex Chapter 7 Spare Parts 7 2 Service Manual 308012En Ed 2 May 2013 ...
Page 146: ...Rosemount Tank Radar Rex Chapter 9 Technical Data 9 10 Service Manual 308012En Ed 2 May 2013 ...
Page 152: ...Rosemount Tank Radar Rex Index 1 6 Service Manual 308012En Ed 2 May 2013 ...
Page 153: ......