4-53
Rosemount Tank Radar Rex
Chapter 4 Service
Service Manual
308012En, Ed.2
May 2013
20
Check the diagnostics Input Register (Input Register 30689) to verify that
the "primary" FCU is active. This is indicated by status bit 12=0. (If the
"backup" FCU is active status bit 12=1).
21
Power down the active FCU.
Comment:
The "backup" FCU switches from inactive to
active.
22
Make sure that the backup FCU is active. This is indicated by status bit
12=1 (see step 20).
23
Power down both FCUs, and then power up the FCUs again starting with
the "primary" FCU as described in step 18.
24
Select the
FCU Slave Database tab
from the Properties menu, and con-
figure the FCU pair like you would configure a single non redundant
FCU. Both FCUs will receive the same data. Switch between the FCUs
to make sure that the same data was stored in both FCUs.
For further information on FCU Installation Procedure see
WinSetup
Reference Manual
.
Summary of Contents for TankRadar Rex DAU 2100
Page 2: ......
Page 3: ...www rosemount tg com Service manual Second edition Copyright May 2013 Rosemount Tank Radar AB ...
Page 8: ...Rosemount TankRadar Rex Contents TOC 4 Service Manual 308012En Ed 2 May 2013 ...
Page 116: ...Rosemount Tank Radar Rex Chapter 4 Service 4 72 Service Manual 308012En Ed 2 May 2013 ...
Page 124: ...Rosemount Tank Radar Rex Chapter 5 Calibration 5 8 Service Manual 308012En Ed 2 May 2013 ...
Page 132: ...Rosemount Tank Radar Rex Chapter 6 Troubleshooting 6 8 Service Manual 308012En Ed 2 May 2013 ...
Page 134: ...Rosemount Tank Radar Rex Chapter 7 Spare Parts 7 2 Service Manual 308012En Ed 2 May 2013 ...
Page 146: ...Rosemount Tank Radar Rex Chapter 9 Technical Data 9 10 Service Manual 308012En Ed 2 May 2013 ...
Page 152: ...Rosemount Tank Radar Rex Index 1 6 Service Manual 308012En Ed 2 May 2013 ...
Page 153: ......