May 2013
Input Register
Measured data is continuously stored in the
Input registers
of DAUs,
RTGs and FCUs. By viewing the contents of device input registers you
can check that the device works properly.
The following summary lists some frequently referred database registers:
Correction values
System configuration
Tank Dimensions
Unit ID
Every RTG, DAU and FCU has a unique Unit ID
which is used to identify the unit when installing a
Rex system.
RTG address
The assigned Modbus slave address for the RTG.
Default value: 246.
DAU address
The assigned Modbus slave address for the associ-
ated DAU. Default value: 247.
FCU address
The assigned Modbus slave address for the associ-
ated FCU. Default value: 245.
Tank Connec-
tion Length,
TCL
The electrical distance from the Transmitter Head
Electronics to the RTG Reference Point (the electri-
cal distance is not equal to the physical distance).
The TCL value is different for different gauge types/
antennas. When configuring a Rex transmitter in
TankMaster WinSetup you can choose between
predefined or user-defined antennas (see Tank-
Master WinSetup Reference Manual). For a user-
defined antenna TCL must be manually entered.
For predefined antennas TCL is automatically set.
Tank Refer-
ence Height (R)
The Tank Reference Height (R) is the distance
between the Tank Reference Point and the Zero
Level (Dipping Datum Point) at the bottom of the
tank.
RTG Reference
Distance (G)
The RTG Reference Distance (G) is the distance
between the Tank Reference Point and the RTG
Reference Point. The RTG Reference Point is
located at the top surface of the customer’s flange
or manhole cover on which the gauge is mounted
as illustrated in Figure 3-12. For Still Pipe Gauges
the RTG Reference point is located at the hand-dip
mark on the Still Pipe Gauge Stand.
G is positive if the Tank Reference Point is located
above the RTG Ref Point. Otherwise G is negative.
Summary of Contents for TankRadar Rex DAU 2100
Page 2: ......
Page 3: ...www rosemount tg com Service manual Second edition Copyright May 2013 Rosemount Tank Radar AB ...
Page 8: ...Rosemount TankRadar Rex Contents TOC 4 Service Manual 308012En Ed 2 May 2013 ...
Page 116: ...Rosemount Tank Radar Rex Chapter 4 Service 4 72 Service Manual 308012En Ed 2 May 2013 ...
Page 124: ...Rosemount Tank Radar Rex Chapter 5 Calibration 5 8 Service Manual 308012En Ed 2 May 2013 ...
Page 132: ...Rosemount Tank Radar Rex Chapter 6 Troubleshooting 6 8 Service Manual 308012En Ed 2 May 2013 ...
Page 134: ...Rosemount Tank Radar Rex Chapter 7 Spare Parts 7 2 Service Manual 308012En Ed 2 May 2013 ...
Page 146: ...Rosemount Tank Radar Rex Chapter 9 Technical Data 9 10 Service Manual 308012En Ed 2 May 2013 ...
Page 152: ...Rosemount Tank Radar Rex Index 1 6 Service Manual 308012En Ed 2 May 2013 ...
Page 153: ......