4-25
Rosemount Tank Radar Rex
Chapter 4 Service
Service Manual
308012En, Ed.2
May 2013
FCC Configuration of Analog Output
In order to use the Analog Output function the cabling must be
disconnected from the ROC board and connected to the Mother Board.
Jumper settings on the FCC are needed in order to configure the card for
Current Loop Output active (internal loop supply) or passive (external
loop supply).
Note!
Make sure that power is turned off before opening the cover.
1
Check if there is any
screw that is sealed.
Contact Rosemount
Tank Gauging before
breaking the seal if
warranty is still valid.
Completely remove
the seal so that it does
not damage the
threads. Loosen the
screws and remove
the cover.
2
Loosen the two
screws which hold the
Electronic Unit.
Summary of Contents for TankRadar Rex DAU 2100
Page 2: ......
Page 3: ...www rosemount tg com Service manual Second edition Copyright May 2013 Rosemount Tank Radar AB ...
Page 8: ...Rosemount TankRadar Rex Contents TOC 4 Service Manual 308012En Ed 2 May 2013 ...
Page 116: ...Rosemount Tank Radar Rex Chapter 4 Service 4 72 Service Manual 308012En Ed 2 May 2013 ...
Page 124: ...Rosemount Tank Radar Rex Chapter 5 Calibration 5 8 Service Manual 308012En Ed 2 May 2013 ...
Page 132: ...Rosemount Tank Radar Rex Chapter 6 Troubleshooting 6 8 Service Manual 308012En Ed 2 May 2013 ...
Page 134: ...Rosemount Tank Radar Rex Chapter 7 Spare Parts 7 2 Service Manual 308012En Ed 2 May 2013 ...
Page 146: ...Rosemount Tank Radar Rex Chapter 9 Technical Data 9 10 Service Manual 308012En Ed 2 May 2013 ...
Page 152: ...Rosemount Tank Radar Rex Index 1 6 Service Manual 308012En Ed 2 May 2013 ...
Page 153: ......