Galaxy A16F-R2422 Installation and Hardware Reference Manual
Subsystem Monitoring
3-10
3.3.1 Default Threshold Values
NOTE:
The threshold values listed below are used to trigger a warning event and
sound the alarm. A different value set is reserved for triggering the
cooling fans to operate at a high rotation speed. The fan speed value set
is not user-configurable.
Table 3-7
shows the default threshold values for the A16F-R2422
subsystem. If any of these values are surpassed, the alarm will sound:
Upper Threshold
Lower Threshold
+3.3V
+3.6V +2.9V
+5V
+5.5V +4.5V
+12V
+13.2V +10.8V
CPU Temperature
90ºC 5ºC
Board Temperature
80ºC 5ºC
Enclosure Ambient
Temperature
40ºC 0ºC
Table 3-7: Default Threshold Values
The thresholds in
Table 3-7
are the default threshold values. To change
these pre-set values, please refer to the
Fibre to SATA RAID Subsystem
Operation Manual
that came with your system. The values set for the
subsystem’s ambient temperature are pre-configured before shipping and
cannot be changed.
3.3.2 Failed Devices
If any of the following devices fail, the audible alarm will be triggered:
•
RAID controller modules
•
Cooling modules
•
PSU modules
•
BBU
•
Hard drives