PROGRAMMING
2.1.9.2 Special mechanical functions
Autoreverse
In the »test« and »auto« modes, a slide with
the „Autoreverse“ function entered in its
program line will automatically be followed
by the first slide of the show. The transition
will be seamless, in other words, there will be
no blackout.
Master-slave operation
In the »test« and »auto« modes, a slide with
one of the two „master-slave“ functions
entered in its program line will cause a con-
trol pulse to be applied to the PC terminal.
With a Rollei adapter cable connected to the
remote-control terminal (RC terminal) of ano-
ther MSC 325 P, MSC 535 P, MSC 300 MSC
300 P, MSC 320 S or MSC 330 P, this may be
used to trigger a forward pulse in a slave. The
pulse may be applied either at the beginning
or in the middle of a dissolve. If the slave also
is a type MSC 325 P, MSC 535 P, MSC 330
P or MSC 300 P projector, this may execute
special functions and can in turn be used as a
master driving an additional slave. Depending
on its operating mode, the latter will use the
dissolve times and, possibly, special functions
either according to the dissolve time set on
its keyboard (manual mode) or the data in its
working memory (test or auto mode). A cer-
tain triggering delay is, however, unavoidable
in a ladder network.
NOTE:
To avoid malfunctions, make sure that
the slave projector has completed its dissolve
or special function before a slave command
is given.
2.1.9.3 Entering special functions
See page 43, top.