2-97
LEF2-300
2
Adjustment
Front Cover Sensor Adjustment
7.
Tighten the screw clockwise until the status of the sensor [C] is ON. When the sensor is ON, [*] mark is displayed.
HCPwFLRAT
* * * * * *
8.
Loosen the screw slowly until the status of sensor [C] is OFF. When the sensor is ON, [*] mark is not displayed.
HCPwFLRAT
* * * *
9.
Loosen the screw counterclockwise half a turn more.
HCPwFLRAT
* * * *
10.
Attach the front cover sensor.