1-14
LEF2-300
1
R
EPLACEMENT
Print Head Replacement
24.
Turn on the power switch and enter the service mode.
25.
Select [SERVICE MENU] > [MOTOR MENU] > [AXIS MOVE] > [HEIGHT], and set the value to [102.0 mm].
AXIS MOVE
HEIGHT
MOTOR MENU
AXIS MOVE
AXIS MOVE
Z:102.0mm
[ ]
[ ENTER ]
[ ENTER ]
SERVICE MENU
MOTOR MENU
[ ][ ]
26.
Unlock the print-head carriage, and move it to the left by hand.
27.
Check that the gap between the head surface and the table top is around 1 mm.
Approx. 1 mm
NOTE
If the print head height is not around 1 mm, perform Chapter 2 "Print Head Height Adjustment".
28.
Perform normal cleaning twice.
FUNCTION
CLEANING
NORMAL
NORMAL
AB
FUNCTION
CLEANING