RML-1
PROGRAMING GUIDELINE
- 32 -
depends on the model used.
!ZZ
(Z three-axis simultaneous-feed command)
<Format>
!ZZ x1,y1,z1,... [terminator]
<Parameter Range>
-8388608
䌾
8388607
<Description>
This moves simultaneously along the three axes from the present
coordinates to the specified coordinate values.
The speed is as set by the V or !VZ command.
When no parameter is present, no operation is performed.
Additionally, the parameters are interpreted as absolute coordinates when
set to absolute coordinates prior to this command and are interpreted as
relative values when set to relative coordinates prior to this command.
<Errors>
For the parameters, three values -- x, y, and z -- make up one set, and
more than one set may be stated.
When the number of parameters is not a multiple of three, the parameters
are interpreted and executed in sequence from the start as x, y, and z, and
the final one or final two results in error 2. The final set is not executed.
<Other Matters>
Similar to the Z command.
The description is also similar to that for the Z command.
<For Reference>
V, !VZ
4;Device Control Commands
4-1;Format of Device Control Commands
[ESC] . K
[ESC] . M P1 ; P2 ; P3 ; P4 ; P5; P6:
[ESC] corresponds to hexadecimal 1B.
Although these are used to illustrate the format, the ESC.M and ESC.T commands
are not supported in RML-1.
<Commands>
This must be in the sequence of "[ESC] . letter/certain symbol".