Abnormal ATC air pressure. Paused...
The air pressure has dropped (during cutting). Adjust the air
pressure, then click [Clear Error]. After recovery, canceling the
pause makes cutting resume.
☞
P. 45, "2-6 Step 5: Supply Compressed Air"
Close magazine cover
An operation that makes the machine perform a task involving
movement was attempted while the magazine cover was open.
After a short wait, this message disappears. Close the cover, then
try the operation again.
Collision may occur if open. Move the table back
toward the front.
An attempt to open the magazine cover was made while the
table was at the rear. Opening the cover while in this state is
impossible because of potential collision with the safety cover
or other areas. After a short wait, this message disappears. Move
the table back toward the front, then try the operation again.
☞
P. 52, "3-2 Mounting the Tool Holders"
No tool
(Not displayed on the VPanel.)
Automatic measurement of tool length was attempted, but no
tools are present in the magazine. Mount tools in the magazine
and redo the operation.
☞
P. 59, "4-2 Automatic Measurement of Tool
Length"
No tool in stocker no. XXX
During a manual tool-change, an attempt was made to grasp a
nonexistent tool. "XXX" is the stocker number. Click [Clear Error],
then redo the operation.
No tool in stocker no. XXX. Paused...
During cutting in the RML-1 mode, an attempt was made to
grasp a nonexistent tool. "XXX" is the stocker number. Click
[Clear Error], then click [Stop Cutting]. Canceling the paused
state and resuming cutting instead of quitting is possible, but
because unintended operation is highly likely, doing so is not
recommended.
No tool in stocker no. XXX. Paused...
(Not displayed on the handy panel.)
During cutting in the NC-code mode, an attempt was made
to grasp a nonexistent tool. "XXX" is the stocker number. Click
[Clear Error], then click [Stop Cutting]. Canceling the paused
state and resuming cutting instead of quitting is possible, but
because unintended operation is highly likely, doing so is not
recommended.
No tool sensor connected
The sensor cable came loose during detection. Click [Clear Error],
then redo detection.
Take tool
An attempt was made to set the Z-axis origin using the tool
sensor while no tool was grasped. Clicking [Clear Error] returns
the machine to the standby state. Grasp a tool, then redo the
operation.
Tool held -- Doing forced release.
(Not displayed on the VPanel.)
Startup is not possible when a tool remains gripped. Follow the
procedures for performing a forced release of the tool.
☞
P. 50, "3-1 Starting and Quitting"
Tool in stocker no. XXX. Cannot return.
During a manual tool-change, a different tool was found to be
already mounted in the tool-return destination. "XXX" is the
stocker number. Click [Clear Error], then remove the offending
tool from the magazine.
Tool sensor not found
The tool failed to reach the sensor. Check the amount of tool
extension and the detection-start position. Click [Clear Error],
then redo detection.
81
Chapter 7 Appendix
7-3 What to Do If...