Loosen
Tighten
Care and Maintenance of the Air Regulator
WARNING
Before removing the bowl, be sure to bleed off the air pressure.
Failure to do so may cause danger of rupture or thrown-off parts.
WARNING
Clean the bowl using a neutral detergent. Never use gasoline, alcohol, thinner, or
any other solvent.
Using a solvent may degrade the bowl and cause danger of rupture.
The air regulator is equipped with a filter that be-
comes filled with trapped material (moisture and
dust) over time. Periodically empty the drain. First,
stop the supply of compressed air, and loosen the
knob at the bottom of the air regulator a little at
a time. Material may spray out of the drain at this
time. Use a cloth or the like to catch the spray
and keep it from scattering. When the drain is
emptied, retighten the knob.
If the interior of the bowl becomes soiled, remove
the bowl and wash it using a neutral detergent.
78
Chapter 7 Appendix
7-1 Daily Care