71
Chapter 4 - Maintenance
4-7 When Moving the Unit
1
If there is media loaded, hold down the [SETUP]
key for 1 second or longer to cancel setup, then
remove the media (see "2-2 Loading Media --
Removing the Media").
2
Press the [MENU] key, and press the [ ] key
to make the following screen appear on the dis-
play.
3
Press the [
] key to make the following screen
appear on the display.
4
Use the [ ] key to select [HEAD WASH], then
press the [ENTER] key.
5
When the display shown in the figure appears,
discard the discharged ink in the drain bottle.
6
Mount the drain bottle and press the [ENTER]
key to display the screen shown in the figure.
Be sure to discard the discharged ink. Attempting
to clean the heads while discharged ink remains may
cause discharged ink to overflow from the bottle.
For more information about how to dispose of dis-
charged ink, see “4-5 Disposing of Discharged Ink.”
MENU
INK CONTROL
INK CONTROL
EMPTY MODE
INK CONTROL
HEAD WASH
EMPTY
DRAIN BOTTLE
REMOVE CARTRIDGE
1 2 3 4 5 6 7 8 9 10 11 12
Before attempting to move the machine, clean the heads. Four optionally available cleaning cartridges are required to clean all
the heads. Each cleaning cartridge can be used to perform cleaning three times.
Do not tilt the machine at a large angle. Ink or discharged fluid remaining in the machine may leak or spill, causing breakdown
or malfunction.