4. Troubleshooting
47
Machine Trouble
Initialization is Not Performed or Initialization Fails
Is the front cover open?
Keep the front cover closed during startup. For
safety, initialization is not performed when the cover
is open at startup.
-
Is the milling bur caught on any-
thing?
The milling bur attached to the spindle unit may fail
to perform initialization if it is caught on the work-
piece or rotary axis unit. Try to detach the milling bur
using the emergency release function in VPanel.
Is anything caught on the spindle
unit or rotary axis unit?
Open the maintenance cover, and make sure that no
workpiece or milling waste is caught.
-
The Operation Button Does Not Respond
Is the front cover open?
This machine restricts some operations when the
front cover is open. Close the cover.
-
Are you wearing gloves?
The operation button will not respond if you are
wearing gloves. Operate the button with a bare hand.
-
VPanel Does Not Recognize the Machine
Is the cable connected?
Make sure that the cables are connected.
Refer to "Setup Guide" ("Connecting the Cables") to
perform the work.
-
Is the driver installed correctly?
If the connection to the computer is not made in
the procedure described, the driver may fail to
install correctly. VPanel will not function normally if
the driver is not configured correctly. Check again
to ensure that the connection was made using the
correct procedure.
Did you verify the connection pro-
cedure when connecting more than
one machine?
There is a possibility that the connection procedure
was performed incorrectly. Make sure that connec-
tions were performed correctly.
Refer to "Setup Guide" ("Connecting Multiple Units")
to perform the work.
-
Was the machine ID changed?
If the machine's ID has been changed, restart the
machine.
Summary of Contents for DWX-51D