FEDL22620-01
ML22620
MUON command
・
Command
0
1
1
1
CH3
CH2
CH1
CH0
1st byte
M7
M6
M5
M4
M3
M2
M1
M0
2nd byte
The MUON command inserts silence between two phrases to be played. This command can be inputted when the NCR
signal of the corresponding channel is "H" level.
Repeated playing back (the SLOOP command) of the MUON command is not possible.
The silence duration (t
mu
) is specified by the M7-M0 bits and can be set from 20ms to 1,024ms in 252 steps at 4ms intervals.
The equation for setting the mute time (t
mu
) is as follows.
However, set the silence setting (M7-M0) to 04h or more (t
mu
≥
20ms).
t
mu
=(2
7
×(M7)+2
6
×(M6)+2
5
×(M5)+2
4
×(M4)+2
3
×(M3)+2
2
×(M2)+2
1
×(M1)+2
0
×(M0)+1)×4ms
The channel settings are as follows:
Channeled
Description
CH0
Setting this bit to 1 inserts silence into channel 0.
CH1
Setting this bit to 1 inserts silence into channel 1.
CH2
Setting this bit to 1 inserts silence into channel 2.
CH3
Setting this bit to 1 inserts silence into channel 3.
Be sure to specify one of the channels for the channel setting (CH0-CH3).
Do not input it to "0" (all “0”) with specifying nothing. If it is input with specifying nothing (all "0"), the command is ignored.
For the timing of the MUON command, refer to the "Playback start timing by MUON command" in the timing chart.
For the timing of continuous playback, refer to the "Continuous playback timing by MUON command" in the timing chart.