Remote Control Commands
R&S
®
AREG100A
265
User Manual 1178.7417.02 ─ 04
If a bit in the ENABle part is 1, and the correesponding EVENt bit is true, a positive
transition occurs in the summary bit. This transition is reportet to the next higher level.
Parameters:
<Enable>
string
Example:
STAT:QUES:ENAB 1
Problems when performing an adjustment cause an entry to be
made in the sum bit.
:STATus:QUEStionable[:EVENt]
<Event>
Queries the content of the EVENt part of the
STATus:QUEStionable
register. This
part contains information on the actions performed in the instrument since the last
readout. The content of the EVENt part is deleted after being read out.
Parameters:
<Event>
string
Example:
STAT:QUES:EVEN?
queries the Status:Questionable:Event register.
:STATus:QUEStionable:NTRansition
<Ntransition>
Sets the bits of the NTRansition part of the STATus:QUEStionable register. If a bit is
set, a transition from 1 to 0 in the condition part causes an entry to be made in the
EVENt part of the register.
Parameters:
<Ntransition>
string
Example:
STAT:QUES:NTR 0
a transition from 1 to 0 in the condition part of the STA-
Tus:QUEStionable register does not cause an entry to be made
in the EVENt part
:STATus:QUEStionable:PTRansition
<PTransition>
Sets the bits of the NTRansition part of the STATus:QUEStionable register. If a bit is
set, a transition from 1 to 0 in the condition part causes an entry to be made in the
EVENt part of the register.
Parameters:
<PTransition>
string
Example:
STAT:QUES:PTR 32767
all transitions from 0 to 1 in the condition part of the STA-
Tus:QUEStionable register cause an entry to be made in the
EVENt part
STATus Subsystem