System Manual 

Division

 

Radiomonitoring and Radiolocation

 

Monitoring System 

R&S

UMS100/120 

with ARGUS-UMS Software 

 

3030.3013.02 3035.1025K02 

3034.0090.02 

 

 

 

Summary of Contents for 3030.3013.02

Page 1: ...3030 3059 72 02 00 System Manual Division Radiomonitoring and Radiolocation Monitoring System R S UMS100 120 with ARGUS UMS Software 3030 3013 02 3035 1025K02 3034 0090 02...

Page 2: ...gennamen sind Warenzeichen der jeweiligen Eigent mer R S is a registered trademark of Rohde Schwarz GmbH Co KG Proper names are trademarks of the respective owners Printed in the Federal Republic of G...

Page 3: ...UMS100 120HF R S UMS100 120SHF is abbreviated with UMS100 120SHF R S ARGUS UMS is abbreviated with ARGUS UMS R S ARGUS is abbreviated with ARGUS R S is a registered trademark of Rohde Schwarz GmbH Co...

Page 4: ......

Page 5: ...2 2 3 Manual operation in Direct Measurement Mode DMM 35 2 3 1 Gain Control 36 2 3 2 Overload Indicator 36 2 3 3 Getting an overview of the spectrum using Scan 37 2 3 4 2D Waterfall Diagram in Scan Mo...

Page 6: ...UMS100 120 120 System Manual Contents 3030 3059 72 02 00 4...

Page 7: ...d connection 33 Figure 2 4 ARGUS UMS connected to a UMS100 120 34 Figure 2 5 Antenna information 35 Figure 2 6 Example of a fast scan for a wide frequency range 37 Figure 2 7 Example Scan for high res...

Page 8: ...0 System Manual Figures 3030 3059 72 02 00 6 Figure 2 34 Analyzing and processing measurement data 62 Figure 2 35 Audio playback 63 Figure 3 1 Service Tool Firmware Update 64 Figure 3 2 Service Tool M...

Page 9: ...k In addition steps are described required for setting up measurements which run automatically on the UMS100 120 The system operator is then only required if a UMS100 120 detects a deviation and has t...

Page 10: ...rk the configuration must take place before it is connected to the network LAN WAN as all UMS100 120 are set with a factory default address 192 168 0 31 One such configuration table is attached in app...

Page 11: ...minimal service work when up and running and for the initial configuration a user interface can be used which is web based and can be started on each UMS100 120 A web browser such as MS Internet Expl...

Page 12: ...on Connect the PC to the UMS100 120 in one of the two following ways Connect the RJ45 socket on the PC to the corresponding socket on the bottom of the UMS100 120 to be configured directly using a cro...

Page 13: ...f the site see Figure 1 3 Acknowledge this certificate by clicking on Yes UMS120 incorporates the modular version of the UMS100 complete system Users therefore can connect to the UMS120 a large range...

Page 14: ...UMS100 120 120 System Manual Operation preparation 3030 3059 72 02 00 12 Then the following Login window appears Figure 1 4 Service Tool UMS100 Login window Figure 1 5 Service Tool UMS120 Login window...

Page 15: ...Firmware components CAUTION For reasons of security a timer runs which triggers an automatic logout after 30 minutes In this case the Login window appears again automatically Now the actual configura...

Page 16: ...orrelated or automated measurements AMMs cannot start because start time has passed already The time must be the actual time in this time zone and not UTC time Check the data again and click on Submit...

Page 17: ...ata again and click on Submit to send CAUTION Make a detailed note of the new access data and store it in a safe place If you forget your details or they get lost access to the UMS100 120 may no longe...

Page 18: ...s ARGUS_MT1 if the UMS100 120 is controlled by ARGUS UMS software for standard ARGUS this may be different When all the fields are filled in and the Connection Type LAN or Dial up Connection has been...

Page 19: ...they can also be entered at a later date CAUTION If you click on Submit once you have entered a new IP Address Subnet Mask and Default Gateway only necessary with a router the data is sent and a conne...

Page 20: ...Put the options CD into the drive of the Control PC After selection of Browse mark the CD drive and the options file in there Activate install And finally click on Submit Figure 1 11 Options for UMS10...

Page 21: ...esponding transducer tables and connection cable types and lengths are considered in the ARGUS control SW Through this correct field strength levels can be displayed In case of overlapping frequency r...

Page 22: ...dBMV A combination of unknown antenna and known R S antenna nevertheless only displays voltage levels Transducer tables from other antenna suppliers can not be entered Now the UMS100 120 has been set...

Page 23: ...the GSM connection which is available once the SIM card has been inserted and the power supply is connected up But further preparation is necessary on the control PC for setting up dial up networking...

Page 24: ...ll a separate outgoing dial up networking using the Assistant for New Connections for each UMS100 120 connected via GSM Open the Network Connections folder using the MS Windows desktop start button or...

Page 25: ...Properties window by clicking it with the right mouse button a At the General tab deselect All devices dial the same number and select the Show symbol for a connection in the information section of th...

Page 26: ...can see in the following Figure 1 15 and click on Create Figure 1 15 Creating a user for dial up Please close the following empty mask with Close For reasons of security you must specify group member...

Page 27: ...ties Member of window In the following the membership Power Users is exclusively entered Click on Add In the following Select Groups window click on Advanced Figure 1 17 Group selection In the expande...

Page 28: ...02 00 26 Figure 1 18 Group selection expanded Close the Select Users window with OK also The name Properties window now only has the entry Power Users Figure 1 19 name Properties with entry Close nam...

Page 29: ...except the modem already configured for the outgoing connection Click on Next to open the next window In the next Incoming VPN connection window you must select VPN connections not permitted Click on...

Page 30: ...gher than in the first A total of two IP addresses must be available as shown in Figure 1 21 Figure 1 21 Assigning an IP address for dial up networking Transfer the other settings from Figure 1 21 Cli...

Page 31: ...still be made in System View tab in Configuration Control Unit Configuration command in the menu Now a new entry for a UMS100 120 can be generated In the Input Field area under Measurement PC overwrit...

Page 32: ...ick on them The procedure is now complete for configuring a UMS100 120 Click on OK to close the window If you want to set up more UMS100 120 begin with the intermediate step each time and carry out th...

Page 33: ...nal windows opened from this window can be placed on the desktop They are not restricted to the size of the standard window You can view information in the help text on the buttons and input fields by...

Page 34: ...s Connect as well as Connect and Activate Depending on the type of connection setting up the UMS100 120 connection takes up to one minute During this time a corresponding window appears For dial up ne...

Page 35: ...tenna configuration when options antenna configurations from the Service Tool were loaded or deleted the data area was emptied with the Clean Up Data Area maintenance function from the Service Tool in...

Page 36: ...of lightening on a yellow background shows the active remote connection The input fields for the geographical coordinates and height can be filled in or changed These parameters are transferred to th...

Page 37: ...ingle frequency measurement level frequency offset Scan with start and stop frequency input and increments for a quick overview Frequency List Scan FLS single frequency measurement for preset frequenc...

Page 38: ...es a critical value where the pre amplifier could produce intermodulation or more critical the analogue digital converter could be overdriven the indicator color is changing from green as shown above...

Page 39: ...h and the increment is important However you can overlook this ratio as the Detector is generally in a max peak position Each signal is then displayed even within larger increments The strongest signa...

Page 40: ...her scan may be necessary over a more limited frequency range with smaller steps 2 3 4 Waterfall Diagram in Scan Mode The examples in chapter 2 3 3 show also the 2D Waterfall Diagram Here the signals...

Page 41: ...own in the line above the scan graphic Figure 2 8 Scan with Max Hold 2 3 6 Listen Mode in Scan Before starting the scan a suitable Demodulation AM FM IF Bandwidth Audio On Audio Transf Rate and Volume...

Page 42: ...is always performed with Max Peak Also the step width should be made small enough to get a fine resolution After starting the scan the center frequency marker is manually set with the mouse or by ent...

Page 43: ...owing options can be selected Set Marker Frequency with switchover to FFM the marker frequency will be the measured frequency Transfer Settings to Single Mode The settings for IF Bandwidth Meas Time e...

Page 44: ...rmed Directly after clicking the Start button the Level is displayed and the audio modulation can be heard if the relevant demodulator is selected and Audio is switched on If the measurement is not ru...

Page 45: ...to the set frequency can be up to some kHz The above example Figure 2 12 shows the frequency of a narrow band FM signal where a measurement is realistic for such kind of transmitters The accuracy can...

Page 46: ...UMS100 120 120 System Manual Operating with ARGUS UMS 3030 3059 72 02 00 44 Figure 2 13 Frequency and offset measurement for AM carrier...

Page 47: ...ned and started first run a test with specific settings in the manual measurement mode There is a range of combinations which exclude one another In addition there are limits for measurement times ban...

Page 48: ...rding 1 65 5 000 data records FFM at 105 7 MHz meas time 20 ms IF bandwidth 100 kHz pre amplifier one level measurement with continuous measurement audio recording with SpeexQ1 quality 0 43 4 970 data...

Page 49: ...data is recorded over a longer time period and for example measurements are carried out only every 15 minutes so as to save memory space Note The total available memory space is not the issue here As...

Page 50: ...to the type signal shall be monitored the Step Width is usually adjusted to the channel spacing of the radio service in that frequency range Do not follow this rule in case that high scan speeds over...

Page 51: ...can then be shown in the form of a graph You can select the graphic type here Figure 2 18 AMM Wizard Step 3 Measurement Definition Step 4 In the last but one configuration window set when and if meas...

Page 52: ...Message function and a Signal Tone are only released on the Control PC if there is an active connection In case SMS is selected and a mobile phone number with information text has been entered the UM...

Page 53: ...tic alarming At the Station input field the name Control Unit is always shown in ARGUS UMS The Delay Time determines a delay after the first alarm has been detected before the UMS100 120 connects to t...

Page 54: ...UMS100 120 120 System Manual Operating with ARGUS UMS 3030 3059 72 02 00 52 Figure 2 20 AMM window other functions...

Page 55: ...can be extended and more specified here Several AMM at different times can be defined using different frequency ranges etc and inserting them into the table Figure 2 21 AMM Timing Definition window T...

Page 56: ...closing a window if changes have been made before After closing a window a question appears if changes should be saved Always accept this question Figure 2 23 AMM Range Definition window In the Measu...

Page 57: ...Operating with ARGUS UMS UMS100 120 120 System Manual 55 3030 3059 72 02 00 Figure 2 24 AMM Further Settings window...

Page 58: ...General Log File Once the AMM has started the connection to the UMS100 120 can be interrupted in the Select window Alarms are still transferred and displayed in the General Log File The General Log Fi...

Page 59: ...pends on whether the alarm goes off when the Limit Line is later overshoot or undershoot in the automatic measurement A positive offset of 5 dB for example pushes the limit up Slight level fluctuation...

Page 60: ...ou want to scan After closing the list it directly can be used for measuring Figure 2 28 Creating a frequency list Instead of entering manually you can also import a frequency list created in Microsof...

Page 61: ...Operating with ARGUS UMS UMS100 120 120 System Manual 59 3030 3059 72 02 00 Figure 2 29 Take over frequencies into the frequency list...

Page 62: ...eneral Log File Figure 2 30 Disk capacity shortage on UMS100 120 Now the following tasks should be done Make a connection to the relevant UMS100 120 if there is not one already Open the Navigator and...

Page 63: ...Operating with ARGUS UMS UMS100 120 120 System Manual 61 3030 3059 72 02 00 Figure 2 31 Measurement result files on UMS100 120 Figure 2 32 Corresponding File Info...

Page 64: ...rtently copy very large files particularly audio which cannot be transferred within an acceptable time due to a slower GSM connection click on Delete to erase the files directly After transferring the...

Page 65: ...dy have a customized user interface geared to their specific purposes which it is essential to keep For these situations there is a fitting solution by using Order Report Module with ARGUS Data Channe...

Page 66: ...to update the version of the control software on the control PC before a Firmware update on the UMS100 120 is performed otherwise operation is no longer possible Before the Firmware update clarify wit...

Page 67: ...l Go to Maintenance and click on Execute that comes after Cleanup Data Area CAUTION If Clean up Data Area has been executed all saved measurement results on the UMS100 120 are lost If the problem has...

Page 68: ...rohde schwarz com or by phone under 49 89 4129 12194 Further information may be available on the following Web Site www ums rohde schwarz com For a comprehensive service or for hardware faults the UM...

Page 69: ...ile network The configuration that is not required is in gray It is advisable to enter these settings beforehand Otherwise a service done locally on the LAN interface of a UMS100 connected by GSM must...

Page 70: ......